75
SEC-1315
Probable Cause
Indicates the call to the EM module to retrieve the IP address failed.
Recommended
Reboot the system to fix this error. If the problem persists contact your switch service provider.
Action
Severity
ERROR
SEC-1315
Message
<timestamp>, [SEC-1315], <sequence-number>,, ERROR, <system-name>, <Name of
command > command failed -<List of databases rejecting distribution > dbs
configured for rejection on this switch
Probable Cause
Indicates there was an attempt to distribute databases to a switch that was configured not to
accept distributions from the fabric.
Recommended
Verify the accept distribution configuration for the listed databases. Use the fddCfg command to
Action
verify and correct the configuration if necessary.
Severity
ERROR
SEC-1316
Message
<timestamp>, [SEC-1316], <sequence-number>,, WARNING, <system-name>, <Policy
Name> policy is conflicting with domain <Domain Number>
Probable Cause
Indicates the newly added switches to the fabric, as specified by Domain Number, have a
conflicting policy with the local switch.
Recommended
Check the conflicting policy and make the new swithces and the local switch policies the same.
Action
Severity
WARNING
SEC-1317
Message
<timestamp>, [SEC-1317], <sequence-number>,, INFO, <system-name>, Inconsistent
fabric, rejecting transaction
Probable Cause
Indicates that either this domain is performing FDD merge or matched domains are not the same
as what CM sees.
Recommended
If a policy conflict exists, resolve it, then wait for the fabric to become stable. Retry the distribution.
Action
Severity
INFO
458
Fabric OS Message Reference
53-1001157-01