Sulb-1025; Sulb-1026; Sulb-1030; Sulb-1031 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os message reference guide v6.2.0 (53-1001157-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

80

SULB-1025

SULB-1025
Message
<timestamp>, [SULB-1025], <sequence-number>,, WARNING, <system-name>, The blade
in slot <Slot number> will reboot with the new firmware.
Probable Cause
Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will
reboot to activate it.
Recommended
Wait for the blade to reboot.
Action
Severity
WARNING

SULB-1026

Message
<timestamp>, [SULB-1026], <sequence-number>, AUDIT, WARNING, <system-name>,
Firmware commit operation started on the blade in slot <Slot number>.
Probable Cause
Indicates the firmwareCommit has started on the specified blade. The operation may be a normal
part of firmwareDownload, or it may have started to repair the secondary partition of the blade if
the secondary partition is corrupted.
Recommended
No action is required.
Action
Severity
WARNING

SULB-1030

Message
<timestamp>, [SULB-1030], AUDIT, WARNING, <system-name>, The switch has rebooted
during relocating the internal firmware image.
Probable Cause
Indicates there may be an error caused by an unexpected disruption of the firmwareDownload
command, for example, by powering the switch off and on in the middle of a firmwareDownload.
The error may also be caused by persistent storage hardware failure or by a software error.
Recommended
The firmwareDownload command will continue after the switch has rebooted. Run the
Action
firmwareDownloadStatus command to monitor progress. If the problem persists, contact your
switch service provider.
Severity
WARNING

SULB-1031

Message
<timestamp>, [SULB-1031], <sequence-number>, AUDIT, WARNING, <system-name>, The
switch is relocating an internal firmware image.
Probable Cause
Indicates the switch has rebooted with the new firmware and is relocating the AP firmware.
498
Fabric OS Message Reference
53-1001157-01

Advertisement

Table of Contents
loading

Table of Contents