69

RCS-1004

RCS-1004
Message
<timestamp>, [RCS-1004], <sequence-number>,, ERROR, <system-name>,
Application(<application name>) not registered.(<error string>)
Probable Cause
Indicates a specified application did not register with RCS.
Recommended
Run the haShow command to view the HA state.
Action
Run the haDisable and the haEnable commands.
Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS
v2.6, v3.1 and greater, and v4.1 and greater.
Run the firmwareDownload command to upgrade the firmware for any switches that do not support
RCS.
Severity
ERROR

RCS-1005

Message
<timestamp>, [RCS-1005], <sequence-number>,, INFO, <system-name>, Phase <RCS
phase>, <Application Name> Application returned <Reject reason>, 0x<Reject code>.
Probable Cause
Indicates a receiving switch is rejecting an RCS phase.
Recommended
If the reject is in ACA phase, wait several minutes and then retry the operation from the sender
Action
switch.
If the reject is in the SFC phase, check if the application license exists for the local domain and if
the application data is compatible.
Severity
INFO

RCS-1006

Message
<timestamp>, [RCS-1006], <sequence-number>,, INFO, <system-name>, State <RCS
phase>, Application <Application Name> AD<Administrative Domain>, RCS CM. Domain
<Domain ID that sent the reject> returned 0x<Reject code>.
Probable Cause
Indicates that a remote domain rejected an RCS phase initiated by an application on the local
switch.
If the reject phase is ACA, the remote domain might be busy and could not process the new
request.
If the reject phase is SFC, the data sent by the application might not be compatible or the domain
does not have the license to support that application.
Recommended
If the reject is in ACA phase, wait several minutes and then retry the operation.
Action
If the reject is in the SFC phase, check if the application license exists for the remote domain and if
the application data is compatible.