Bl-1010; Bl-1011 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os message reference guide v6.2.0 (53-1001157-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

5

BL-1010

Recommended
Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1010
Message
<timestamp>, [BL-1010], <sequence-number>,, WARNING, <system-name>, Blade in slot
<slot number> inconsistent with the hardware settings.
Probable Cause
Indicates that a failover occurred while some hardware changes were being made on the previously
active control processor (CP) (such as changing the domain ID).
Recommended
No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
Action
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
Severity
WARNING

BL-1011

Message
<timestamp>, [BL-1011], <sequence-number>, FFDC, CRITICAL, <system-name>, Busy
with emb-port int. for chip <chip number> in minis <minis number> on blade <slot
number>, chip int. is disabled. interrupt status=0x<interrupt status>.
Probable Cause
Indicates that too many interrupts in the embedded port caused the specified chip to be disabled.
The probable cause is too many abnormal frames; the chip is disabled to prevent the control
processor (CP) from becoming too busy.
Recommended
Make sure to capture the console output during this process.
Action
Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port.
Run the systemVerification command to verify that the blade or switch does not have hardware
problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the nonbladed switch.
Severity
CRITICAL
52
Fabric OS Message Reference
53-1001157-01