Severity
WARNING
EM-1061
Message
<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type
your standby CP, then reboot or run haSyncStart.
Probable Cause
Indicates a blade in the system is not supported by the release on the standby control processor
(CP).
Recommended
Remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken,
Action
this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the system
will remain out of synchronization.
Severity
WARNING
EM-1062
Message
<timestamp>, [EM-1062], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted as it exceeds the maximum support limit of <Limit> blades
with Blade ID <Blade Type Id> in the chassis.
Probable Cause
Indicates too many blades of a particular type are in the system.
Recommended
Remove the faulted blade.
Action
Severity
CRITICAL
EM-1063
Message
<timestamp>, [EM-1063], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted because it exceeds the maximum support limit of <Limit>
blades with Blade IDs <Applicable blade Type IDs> in the chassis.
Probable Cause
Indicates too many blades of a set of particular types are in the system.
Recommended
Remove the faulted blade.
Action
Severity
CRITICAL
EM-1064
Message
<timestamp>, [EM-1064], <sequence-number>,, CRITICAL, <system-name>, Blade:<slot
ID> is being powered off (based on user configuration) upon receiving a HW ASIC
ERROR, reason:<Fault reason>.
Fabric OS Message Reference
53-1001157-01
EM-1061
<Blade Type Id>
or upgrade
17
119