PS System Messages
PS-1000
Message
<timestamp>, [PS-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, Failed
to initialize Advanced Performance Monitoring.
Probable Cause
Indicates an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor has failed to initialize.
Recommended
The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to
Action
reinitiate the firmware.
Severity
CRITICAL
PS-1001
Message
<timestamp>, [PS-1001], <sequence-number>,, INFO, <system-name>, Advanced
Performance Monitoring configuration updated due to change in PID format
Probable Cause
Indicates the PID format was changed.
Recommended
No action is required. Refer to the Fabric OS Administrator's Guide for more information about the
Action
PID format.
Severity
INFO
PS-1002
Message
<timestamp>, [PS-1002], <sequence-number>,, INFO, <system-name>, Failed to
initialize the tracing system for Advanced Performance Monitoring.
Probable Cause
Indicates an unexpected software error has occurred in Advanced Performance Monitoring. The
Performance Monitor tracing system has failed to initialize.
Recommended
Tracing will not be available for Advanced Performance Monitoring, but other functions should
Action
function normally. To retry activating tracing, reboot (or fail over) the CP.
Severity
INFO
PS-1003
Message
<timestamp>, [PS-1003], <sequence-number>,, WARNING, <system-name>, Failed to set
end-to-end monitoring mask on ISL ports.
Fabric OS Message Reference
53-1001157-01
Chapter
66