Severity
ERROR

SPC-3014

Message
<timestamp>, [SPC-3014], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: RNG compare failure: successive
values match.
Probable Cause
Indicates the Crypto Module internal random number generator failed.
Recommended
Contact technical support.
Action
Severity
ERROR

SPC-3015

Message
<timestamp>, [SPC-3015], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: RSA pairwise key generation test
failure.
Probable Cause
Indicates the Crypto Module could not generate its internal key pair.
Recommended
Contact technical support.
Action
Severity
ERROR