EM-1058
Message
<timestamp>, [EM-1058], <sequence-number>,, WARNING, <system-name>, Switch gets
reset:
Probable Cause
The switch is automatically reset due to known resetable transient errors, such as an
application-specific integrated circuit.(ASIC) parity. error.
Recommended
No action is required if the switch does not reach the reset threshold for the switch/blade. If the
Action
reset threshold is reached on the switch/blade, the switch/blade will be faulted and should be
replaced.
Severity
WARNING
EM-1059
Message
<timestamp>, [EM-1059], <sequence-number>, FFDC, CRITICAL, <system-name>,
Incompatible unit in
Probable Cause
Indicates that a field-replaceable unit (FRU) inserted in the specified slot is not compatible with the
switch software. The blade will not be used.
Recommended
Replace the blade. Make sure the replacement is compatible with your switch type.
Action
Severity
CRITICAL
EM-1060
Message
<timestamp>, [EM-1060], <sequence-number>,, WARNING, <system-name>, Stopping
synchronization of the system due to blade incompatibility with software version
on standby CP.
Probable Cause
A blade in the system is not supported by the release on the standby control processor (CP).
Recommended
Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is
Action
taken, this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the
system will remain out of synchronization.
Severity
WARNING
EM-1061
Message
<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type
your standby CP, then reboot or run haSyncStart.
Probable Cause
A blade in the system is not supported by the release on the standby control processor (CP).
Fabric OS Message Reference
53-1000600-01
<Fault reason>
<FRU Id>
faulted.
<Blade Type Id>
12
EM-1058
or upgrade
91