Chapter 5
Removal and Replacement Procedures
Be sure to place a plastic insulator over the smaller terminal block even if you are even if you are not
Note
attaching DC-input wires to it; this ensures that the plastic insulator is available for future use.
b.
Wrap the large perforated flaps around each pair of conductors, inserting each locking tab into rear
of slot. Pull the tab until the cover is secured around the power cabling trim and discard excess tab
plastic.
From the right side of the power supply, connect the ground wire to the ground
c.
Figure 5-79
Terminal
block cover
Power
switch
From the right side of the power supply, connect the DC-input wires to TB1
d.
Figure
Note
Place and secure left and right inner terminal block cover.
e.
f.
Using the cable tie provided, place the cable tie through the slot at the top of the right terminal block
cover and secure the wiring to the left terminal block.
Secure outer block cover.
g.
OL-4503-26
DC-Input Wire Connections for 2700-W DC-Input Power Supply, Right Side of Power
Plastic
insulator
I
0
INP UT OK
1
Captive
installation
screw
Bay
5-79) in this order:
Negative (-)
Positive (+)
When you tighten the terminal nuts, make sure they are snug. Do not over tighten them.
Recommended torque strength is 20 inch-pounds. Over tightening the terminal nuts can
break the terminal block (Maximum torque: 36 inch-pounds).
FAN
OUT PUT
2
3
OK
FAIL
( ) Ground
Cisco 7600 Series Router Installation Guide
Removing and Replacing the Power Supply
(Figure
Power leads
attached to
terminal block
(+) Positive
( - ) Negative
(+) Positive
( - ) Negative
(Figure 5-76
5-79).
and
5-77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

76037603-s760476067606-s7609 ... Show all

Table of Contents