Removing and Replacing the Power Supply
Attach the appropriate lugs to the DC-input wires. The maximum width of a lug is 0.600 inch (15.2 mm).
Step 6
The wire should be sized according to local and national installation requirements. Use only copper wire.
Note
Step 7
Connect the DC-input wires to the 4500 W power supply terminal block
Ground
Negative (-)
Positive (+)
When you tighten the terminal nuts, make sure they are snug. Do not over tighten them. Recommended
Note
torque strength is 20 inch-pounds. Over tightening the terminal nuts can break the terminal block
(Maximum torque: 36 inch-pounds).
Depending on which side you are connecting the DC-input wires, be sure that the DC-input wires rest in
the appropriate cable holder.
Secure the ground cable to the cable holder with the two cable-ties.
Step 8
Warning
When installing the unit, the ground connection must always be made first and disconnected last.
Step 9
Retrieve the cable holder covers from the plastic bag and attach to the front panel at the locations shown
in
Figure
Note
Secure the terminal block cover using four screws and the terminal block barriers with two screws each.
Step 10
Turn on the DC inputs and verify power supply operation by checking that the power supply front panel
Step 11
LEDs are in the following states:
INPUT OK LED is green
FAN OK LED is green
OUTPUT FAIL LED is not lit
If the LEDs indicate a power problem, see the
Cisco 7600 Series Router Installation Guide
5-64
For 4500 W power supplies, use fine-stranded copper conductors rated for 45-degrees Celsius
for North American installations.
5-60.
If the cable holder illustrated as number 2 and 8 in
please use a long cable tie to secure the cable holders as shown in
Chapter 5
Removal and Replacement Procedures
Figure 5-66
is loose on the DC input cables,
"Identifying Startup Problems" section on page
(Figure
5-66) in this order:
Figure
5-66.
4-2.