• [Scene Change]
The recall status of the specified scene is transmitted via GPI output.
[Parameter] specifies the scene for which the recall status is to be output.
[Threshold] and [Polarity] are not available.
[Terminal] determines how the GPI voltage will be output in response to parameter changes.
Terminal
When the current scene is the same as the scene specified by [Parameter] the output will
be high, and when different the output will be low.
When the current scene is the same as the scene specified by [Parameter] the output will
be low, and when different the output will be high.
A pulse
[Parameter].
A pulse
[Parameter].
• [GPI Lock]
The GPI Lock status is transmitted via GPI output.
[Parameter], [Threshold], and [Polarity] are not available.
[Terminal] determines how the GPI voltage will be output in response to parameter changes.
Terminal
When GPI Lock is ON the output will be high, and when OFF the output will be low.
When GPI Lock is ON the output will be high, and when OFF the output will be low.
*1 Pulse waveform 1
HI
LO
Event Schedule
Event Schedule is shown when [GPI OUT] is set in "Event Scheduler."
See "Event Scheduler" on page
User Defined Button
User Defined Button is shown when [GPI OUT] is set in "User Defined Button."
See "User Defined Button (User Defined Parameters)" on page
Event Log
Event Log is shown when [GPI OUT] is set in "Event Logger."
See "Event Logger" on page
*1
will be output when the current scene is the same as the scene specified by
*2
will be output when the current scene is the same as the scene specified by
250 msec
116.
111.
Chapter 3 Main Panel Window
GPI Output
GPI Output
*2 Pulse waveform 2
HI
LO
250 msec
98.
DME Designer Owner's Manual