Chapter 3 Main Panel Window
• [Scene Change]
• [Scene Increment]
82
DME Designer Owner's Manual
GPI input can be used to recall a specified scene.
[Parameter] specifies the number of the scene to be recalled.
[Min] and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN rises
from below to above the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN drops
from above to below the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Same as
.
Same as
.
GPI input can be used to increment the scene number.
[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
The scene number will be incremented each time the voltage applied to GPI IN rises from below to
above the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The scene number will be incremented each time the voltage applied to GPI IN drops from above to
below the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Same as
.
Same as
.
Median voltage
Trigger
Trigger
Median voltage
Median voltage
Trigger
Trigger
Median voltage