Translate Table - Printronix P7010 User Manual

P7000 series psa3 printers
Hide thumbs Also See for P7010:
Table of Contents

Advertisement

FF After Job
Determines the print position after an operator-initiated local copy (print
screen function).
Off (default). Performs an automatic new line command after completing
a print buffer (unless a new line, form feed, or carriage return command
was the last one executed). The printer is set to print at print position 1 of
the next line.
On. Performs an automatic form feed command unless a form feed was
the last one executed. The printer is set to print at print position 1 of the
first line on the next form.
CR, EM, & NL (3287 only)
CR (Carriage Return), EM (Error Message), and NL (New Line) specify that
the printer treat the CR, EM, and NL control codes either as spaces or as
control codes.
On (default). Treats the CR, EM, and NL commands as control codes.
Off. Treats the CR, EM, and NL commands as spaces.

Translate Table

Defines which translate table to use for printing.
Default (default). Translates data by using the default table of the current
character set.
Downloaded. Translates data from EBCDIC to internal code by using the
downloaded translate table.
Host Override
Determines whether the printer accepts certain commands sent by the host or
continues to use the current operator panel settings.
Disable (default). Allows the following host commands to override
operator panel settings: line length, forms length, lines per inch (LPI),
characters per inch (CPI), print quality, and text orientation. Note the
information appearing on the message display may not match the data
stream setting. No values will change upon initial selection of the disable
option.
Enable. The operator panel settings override the host commands.
Format Control
Enables the printer to reflect the same spacing as CTPC model printers after
absolute and relative move commands are executed.
Disable (default). Reflects distance, generated by the IGP/VGL feature,
IGP/PGL feature, and Hex Transparent control code sequence, in the
new position (after horizontal and vertical tabs are executed).
Enable. Does not reflect distance, generated by the IGP/VGL feature,
IGP/PGL feature, and Hex Transparent control code sequence, in the
new position (after horizontal and vertical tabs are executed).
Coax Emulation