P-Series Emulation (With LG)
Printer
Protocol
(from page 138)
P-Series
Control Code
Control Code
06
08
8.0 LPI*
Elongated*
10.3 LPI
Backspace
6.0 LPI
P-Series
EVFU Select
SFCC
1*
Enable*
(0-7F hex)
Disable
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can
select an alternate line spacing of 6, 8, or 10.3 LPI.
Control Code 08
Control Code 08 defines the function of ASCII code hex 08 (BS). You can
define the code to output the following character:
•
Elongated (default).
•
Backspace.
Define CR Code
This option controls the action of the printer when it receives a Carriage
Return code (hex 0D) from the host computer. If this feature is enabled, each
time the printer receives a carriage return, it inserts an additional Line Feed
code (hex 0A) into the data stream. Do not use this feature if the host
computer sends Line feeds to the printer.
•
CR = CR (default). Does not insert an extra line feed after each carriage
return.
•
CR = CR + LF. Inserts an extra line feed after each carriage return. The
next print position will be print position 1 of the next line.
Define CR
Auto LF
Code
CR = CR*
Disable*
CR = CR + LF
Enable
Alt. Set
Character
Set
80-9F
Control Code*
(see page 151)
Printable
P-Series Emulation (With LG)
* = Factory Default
Define LF
Overstrike
Code
Enable*
LF = CR + LF*
Disable
LF = LF
SFCC d
Command
Even dot plot*
Double high
145
Need help?