Lcd Message Troubleshooting Table - Printronix ProLine 5 Series Manual

Line matrix printer
Table of Contents

Advertisement

Table 6–1 LCD Message Troubleshooting Table (continued)
Displayed Message
EXHAUST FAN FLT
(Cabinet model only)
FIRMWARE ERROR*
FM HEADER ERROR
FRAMING ERROR
GRF CHK ERROR
PRESS STOP
HAM. COIL OPEN*
HAMMER COIL BAD
#, #, #
HMR BANK FAN FLT
08 HOLD PRINT
TIMEOUT
Troubleshooting
Can
User
Explanation
Correct?
Yes
Sensors cannot detect
current in fan circuit.
No
Application software tried
to perform an illegal printer
function or damaged
memory detected on
board.
No
Applications software has
violated header
parameters.
Yes
Serial framing error. (Serial
interface.)
Yes
Printer has received a
non–printable character.
No
Electrical malfunction of
one or more hammer coils.
No
Hammer coil # failed
current test at power up.
Yes
Sensors cannot detect
current in fan circuit.
Yes
Printer was off–line more
than 10 minutes and the
"Intervention Required"
parameter is set to "Send
to Host."
Solution
Power off the printer and remove
the paper path. Check that the
fan cable connector is connected.
Check for obstruction of vents
and fan airway, and remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message recurs,
contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Contact your system
administrator
Check your serial host interface
parameter settings; if necessary,
adjust them so that they match
the settings of the attached host.
Press CLEAR and then ONLINE.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Check that fan cable is
connected. Check for obstruction
of vents and fan airway; remove
any obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message recurs,
contact your authorized service
1
representative.
Press ONLINE to put printer in
online state.
6–7