LinePrinter Plus Emulation (With PCL-II)
Upr. Case Select
Controls how the printer handles lowercase characters it receives from the
host computer. When enabled, all characters will be printed in uppercase.
•
Disable (default). Prints lowercase characters received from the host
computer as lowercase, and prints uppercase characters received from
the computer as uppercase.
•
Enable. Prints lowercase characters received from the host computer as
their corresponding uppercase equivalents; uppercase characters
received from the computer print as uppercase.
Slew Relative
"Slewing" is rapid vertical paper movement. This parameter determines the
number of lines slewed (either 1-15 lines or 1-16 lines) when an EVFU Slew
Relative command is received. The options include:
•
1-15 Lines (default)
•
1-16 Lines
Serial Matrix Emulation
Printer
Protocol
(from page 138)
Serial
Matrix
Control Code
Define CR
06
Code
8.0 LPI*
CR = CR*
10.3 LPI
CR = CR + LF
6.0 LPI
Alt. Set
Character
80-9F
Control Code*
(see page 157) Even dot plot*
Printable
154
Auto LF
Overstrike
Enable*
Enable*
Disable
Disable
ESC d
Set
command
Double high
* = Factory Default
Define LF
Printer
Code
Select
LF = LF*
Disable*
LF = CR + LF
Enable