Property Subgroup 2.3.1.2.1.N System Status Device State Information; Property 2.3.1.2.1.1 Device Operational Status - Magtek DynaFlex II Go Programmer's Manual

Secure card reader
Hide thumbs Also See for DynaFlex II Go:
Table of Contents

Advertisement

8 - Configuration

8.6.3 Property Subgroup 2.3.1.2.1.n System Status Device State Information

8.6.3.1 Property 2.3.1.2.1.1 Device Operational Status

Table 8.6-16 - Property 2.3.1.2.1.1 Device Operational Status
Property OID 2.3.1.2.1.1 / 0x020301020101
Name
Device Operational Status
The device uses this property to report its operational status.
Online is the status the manufacturer populates in this property before shipping, and is
the result of the device going through processes that configure its security subsystems
and features. In this state, the device is fully functional and can perform transactions.
Description
Offline means the device is no longer fully functional and can no longer perform
transactions. The device automatically transitions to this state if it detects a problem
with security or any of the subsystems it checks. For example, trying to open the device
triggers a tamper response, which causes the device to change its operational status to
Offline. To retrieve more information about the cause of an Offline status, the host can
retrieve Property 2.3.1.2.1.2 Offline Status Detail.
Securing Key None
Min. Len (b)
1
Max. Len (b) 1
Data Type
Binary
0x01 = Offline
Valid Values
0x02 = Online
Default
None
Table 8.6-17 - Get Request Example
AA00 8104 0155D101 840F D101 8501 02 8704 03010201 8902 C100
Table 8.6-18 - Get Response Example
AA00 81048255D101 820400000000 84820010 D101 850102 870403010201 8903 C101 02
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Property Description
Example (Hex)
Example (Hex)
Page 280 of 301 (D998200597-102)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DynaFlex II Go and is the answer not in the manual?

Questions and answers

Table of Contents