8 - Configuration
Table 8.3-108 - Set Request Example
AA00 81040155D111 8410 D111 8501 01 8704 02070101 8903 C20101
Table 8.3-109 - Set Response Example
AA00 8104 8255D111 8204 00000000 84820010 D111 8501 01 8704 02070101 8903 C201 01
8.3.5.3 Property 1.2.7.1.1.3 Device Reset Will Occur Soon Notification Control
Table 8.3-110 - Property 1.2.7.1.1.3 Device Reset Will Occur Soon Notification Control
Property OID 1.2.7.1.1.3 / 0x010207010103
Name
Device Reset Will Occur Soon Notification Control
The host can use this property to control behavior of the Device Reset Will Occur Soon
notification in Notification 0x1001 - Device Information Update.
Description
See 24 Hour Automatic Reset PCI Requirement for more information.
Changes to this property do not take effect until the device is power cycled or reset.
Securing Key None
Min. Len (b)
1
Max. Len (b) 1
Data Type
Binary
0x00 = Never send this notification.
Valid Values
0x01..0xFF = Number of minutes before a reset to send the notification message.
Default
0x03
Table 8.3-111 - Get Request Example
AA 00 81 04 01 55 D1 01 84 0F D1 01 85 01 01 87 04 02 07 01 01 89 02 C3 00
Table 8.3-112 - Get Response Example
AA 00 81 04 82 55 D1 01 82 04 00 00 00 00 84 82 00 10 D1 01 85 01 01 87 04 02 07 01 01 89 03 C3
01 05
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Example (Hex)
Example (Hex)
Property Description
Example (Hex)
Example (Hex)
Page 233 of 301 (D998200597-102)