7 - Notifications
Cat Rsn
Det Ext
01
07
00
00
Category 0x04 Temperature contains notification detail codes involving temperature reporting. Each
possible notification has a unique Reason value:
•
Reason 0x00 = Temperature out of range
04
00
00
00 Temperature, Out of Range, Low Warning, Temperature
04
00
01
00 Temperature, Out of Range, High Warning, Temperature
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Barcode Reader, Read Barcode Result, Type, Reserved (BCR Only)
•
Type 0x00 = Unknown
•
Type 0x01 = MagTek
•
Type 0x02 = EMV
The barcode reader has successfully read a barcode. In this case, the device
includes barcode data in the Notification Payload portion of the Notification
Message. If the data is encrypted, the data is in the format described in Table
7.4-5. Data that is not encrypted is in the format described in Table 7.4-6.
The device sends this notification when the device's temperature falls below
the temperature set in Low Temperature Notification Level (1.2.7.1.4.1). The
temperature reported is in Celsius.
The device sends this notification when the device's temperature rises above
the temperature set in High Temperature Notification Level (1.2.7.1.4.2). The
temperature reported is in Celsius.
Page 167 of 301 (D998200597-102)