8 - Configuration
Table 8.3-232 - Set Response Example
AA00 8104 8255D111 8204 00000000 84820010 D111 8501 01 870402070104 8903 C201 2D
8.3.5.10
Property 1.2.7.1.4.3 Device Temperature Notification Repeat Interval
Table 8.3-140 - Property 1.2.7.1.4.3 Device Temperature Notification Repeat Interval
Property OID 1.2.7.1.4.3 / 0x010207010403
Name
Device Temperature Notification Repeat Interval
While the device's temperature is outside of the range defined by Device Low
Temperature Notification Level (1.2.7.1.4.1) and Device High Temperature Notification
Level (1.2.7.1.4.2), notifications will be sent to the host. This property sets the period
Description
between notifications.
The Device Temperature Notification Repeat Interval takes effect immediately after the
host changes it.
Securing Key None
Min. Len (b)
1
Max. Len (b) 1
Data Type
Binary
0x00
Valid Values
0x0F .. 0xFF Repeat period in seconds. Must be multiple of 0x0F (15).
Default
0x1E (30 seconds)
Table 8.3-141 - Get Request Example
AA00 8104 0155D101 840F D101 8501 01 8704 02070104 8902 C300
Table 8.3-235 - Get Response Example
AA00 8104 8255D101 8204 00000000 84820010 D101 8501 01 8704 02070104 8903 C301 1E
Table 8.36 - Set Request Example
AA00 81040155D111 8410 D111 8501 01 8704 02070104 8903 C301 1E
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Example (Hex)
Property Description
Send once. Do not repeat.
Example (Hex)
Example (Hex)
Example (Hex)
Page 241 of 301 (D998200597-102)