8 - Configuration
8.3.5.7 Property 1.2.7.1.3.1 Maximum Battery Charge Level (Deprecated)
Table 8.3-129 - Property 1.2.7.1.3.1 Maximum Battery Charge Level (Deprecated)
Property OID 1.2.7.1.3.1 / 0x010207010301
Name
Maximum Battery Charge Level
This OID has been deprecated. The OID can be written or read but it will have no effect
of the device's behavior.
The host can use this property to control the maximum charge level for the battery. All
charge percentages reported or displayed will use this percentage as 100% charged.
Description
Setting this value to lower than 0x64 (100%) will increase the life of the battery but
reduce the run time when running from the battery.
The Maximum Battery Charge Level takes effect immediately after the host changes it.
Securing Key None
Min. Len (b)
1
Max. Len (b) 1
Data Type
Binary
Valid Values 0x0A..0x64
0x64 (100%) if WLAN device
Default
0x50 (80%) for all other devices
Table 8.3-130 - Get Request Example
AA00 8104 0155D101 840F D101 8501 01 8704 02070103 8902 C100
Table 8.3-131 - Get Response Example
AA00 8104 8255D101 8204 00000000 84820010 D101 8501 01 8704 02070103 8903 C101 50
Table 8.3-132 - Set Request Example
AA00 81040155D111 8410 D111 8501 01 8704 02070103 8903 C101 50
Table 8.3-222 - Set Response Example
AA00 8104 8255D111 8204 00000000 84820010 D111 8501 01 8704 02070103 8903 C101 50
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Property Description
Example (Hex)
Example (Hex)
Example (Hex)
Example (Hex)
Page 238 of 301 (D998200597-102)