8 - Configuration
8.6.2.2 Property 2.3.1.1.2.2 Tamper Sensors Activated
Table 8.6-10 - Property 2.3.1.1.2.2 Tamper Sensors Activated
Property OID 2.3.1.1.2.2 / 0x020301010202
Name
Tamper Sensors Activated
Description
A device that is operating normally should always have its tamper sensors activated.
Securing Key None
Min. Len (b)
1
Max. Len (b) 1
Data Type
Binary
0x00 = Tamper Sensors Not Activated
Valid Values
0x01 = Tamper Sensors Activated
Default
None
Table 8.6-11 - Get Request Example
AA00 8104 0155D101 840F D101 8501 02 8704 03010102 8902 C100
Table 8.6-12 - Get Response Example
AA00 81048255D101 820400000000 84820010 D101 850102 870403010102 8903 C101 01
DynaFlex II Go| Secure Card Reader | Programmer's Manual (COMMANDS)
Property Description
Example (Hex)
Example (Hex)
Page 278 of 301 (D998200597-102)