5. Press the DATA/SHIFT key for less than one second to display the
current detection data. Press the DATA/SHIFT key again for less
than one second, and the display will return to show as in step 3 or 4
above.
6. Press the Up Arrow or Down Arrow key to adjust the offset.
Carefully adjust the offset while monitoring the torque reference
monitor signal.
7. When the current offset adjustment has been completed for the U-
phase (Cu1_0) and V-phase (Cu2_0), press the DATA/SHIFT key
to return to the Auxiliary Function mode display.
This completes the manual adjustment of the motor current detection
offset.

7.2.12. Write Protection Setting

The write protection setting is used to prevent careless changes of
parameters. Pn
become write protected by setting the parameter Fn010.
Password setting values are as follows:
• "0000": Write enabled (releases write protected mode.)
• "0001": Write prohibited (parameters become write protected at the
next power ON.)
Follow the procedure below to set the write protection feature.
1. Press the MODE/SET key to select the Auxiliary Function mode.
2. Press the Up Arrow or Down Arrow key to select the parameter
Fn010.
Chapter 7: Using the Panel Operator
DATA/SHIFT key
Displays
alternately
parameters and some of the Fn
7-36
Data display
Data setting change
parameters