Follow the procedure below to execute the origin search.
1. Press the MODE/SET key to select the Auxiliary Function mode.
2. Press the Up Arrow or Down Arrow key to select the parameter
Fn003.
3. Press the DATA/SHIFT key for a minimum of one second, and the
display will be as shown below.
4. Press the DSPL/SET key, and the display will change as shown
below. Now it is ready for executing the origin search.
5. Hold down Up Arrow or Down Arrow key to execute the origin
search. When the parameter is set to Pn000.0 = 0 (default), pressing
the Up Arrow key will rotate the motor in forward direction.
Pressing the Down Arrow key will rotate the motor in reverse
direction. When the parameter is set to Pn000.0 = 1, the rotation of
the motor is reversed.
6. Press the DATA/SHIFT key for a minimum of one second to return
to the Auxiliary Function mode display.
This completes the origin search operation.