XtraDrive User Manual
• Connecting an optocoupler output circuit
An optocoupler output circuits are used for servo alarm, servo ready,
and other sequence output signal circuits.
Connect an optocoupler output circuit through a relay or line
receiver circuit.
Note: The maximum allowable capacities for optocoupler output circuits are:
Voltage: 30V
Current: 50mA
• Connecting two XtraDrives (master-slave mode)
Connect output of "master" XtraDrive to "slave" XtraDrive's input.
• Connecting an external load to XtraDrive's output.
Maximum current: 50mA.
DC
DC
3-22