Setting 7: Traveling Application - Omron V1000 User Manual

Compact vector control drive 200 v class three-phase input 0.1 to 15 kw, 200 v class single-phase input 0.1 to 4.0 kw, 400 v class three-phase input 0.2 to 15 kw
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

4.6 Application Selection
u

Setting 7: Traveling Application

No.
A1-02
Control Mode
b1-01
Frequency Reference Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Cycle
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
H1-05
Multi-Function Digital Input Terminal S5 Function
H1-06
Multi-Function Digital Input Terminal S6 Function
H2-02
Terminals P1 Function Selection
L3-04
Stall Prevention Selection during Decel
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection
L8-38
Carrier Frequency Reduction
L8-41
Current Alarm Selection
<1> Disable L8-05 for single-phase models.
No.
b1-01
Frequency Reference Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
86
OFF
S1-SC
UP
Input
OFF
Fast/Slow
S6-SC
Output frequency
0
Output
Frequency Detection 2
(H2-03 05)
P2-PC
Holding brake
Closed
Figure 4.12 Holding Brake Time Chart
Table 4.17 Traveling: Parameters and Settings
Parameter Name
Table 4.18 Traveling: User Parameters (A2-01 to A2-16):
Parameter Name
ON
ON
b6-02
d1-01 (Enabled when b1-01 = 0)
d1-03
b6-01
b2-01
L4-01
DC Injection braking
OFF
ON
Open
Closed
0: V/f Control
0: Operator
3.0 s
3.0 s
0: Heavy Duty
2: 5 kHz
6.0 Hz
30.0 Hz
50.0 Hz
3: Multi-Step Speed 1
4: Multi-Step Speed 2
37: During frequency output
0: Disabled
<1>
1: Enabled
1: Triggered when a single phase is lost
1: Enabled below 6 Hz
1: Enabled (alarm output)
No.
d1-03
Frequency Reference 3
E2-01
Motor Rated Current
H1-05
Multi-Function Digital Input Terminal S5 Function
H1-06
Multi-Function Digital Input Terminal S6 Function
H2-01
Terminals MA, MB, and MC Function Selection
L1-01
Motor Overload Protection Selection