5. Setting Procedure
5.1 TEACH Mode
1
Set the mode selector to TEACH.
2
Make the automatic teaching and model size
settings on the DIP switch.
If using an F10-C30/C35/C50/C55, go to
step
If using an F10-C20/C25, go to step
3
Set the measurement item/bank number
selection switch to PATT/BANK.
Bank No. 0 will be displayed.
4
Press the UP/DOWN select buttons to set
the bank number.
5
Use the measurement item (bank number)
selection switch to set the measurement method.
3
to set the bank number.
Banks
Each F10-C30/C35/C50/C55
Sensor has eight banks for
storing data, and a different
threshold value can be stored
in each of the eight banks.
Use this function to take
measurements under various
conditions. You can switch
operation simply by switching
banks.
19
Measurement Items: PATT/BANK
Checking the degree of
suitability of the model
Optimum
for a
model
5
Not fit for
a model
Locate the sensing object in the
sensing area so that the degree
of suitability for a model will be
indicated.
6
Press the teach/display button after locating
the sensing object in the sensing area.
Teaching successful
8
7
6
Press the
5
teach/display
4
button .
3
2
1
The level indicators are all lit for
0.5s and the buzzer sounds
twice.
Teaching unsuccessful
The threshold indicators all flash
while the buzzer sounds four times.
The contrast is insufficient. Change
the location of the Sencor and try
again.
20
8
7
6
Buzzer
sounds
5
4
3
2
1
8
7
6
Buzzer
5
sounds
4
3
2
1