Omron V1000 User Manual page 314

Compact vector control drive 200 v class three-phase input 0.1 to 15 kw, 200 v class single-phase input 0.1 to 4.0 kw, 400 v class three-phase input 0.2 to 15 kw
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
F6-30 PROFIBUS node address
PROFIBUS Clear Mode
F6-31
Selection
PROFIBUS Data Format
F6-32
Selections
F6-35 CANopen Node ID selection Sets the Node ID for a CANopen option
F6-36 CANopen Communications
speed
F6-40 CompoNet Node ID
F6-41 CompoNet Speed
F6-50
DeviceNet MAC Address
<58>
F6-51
Device Net Communications
<58>
Speed
F6-52
DeviceNet PCA setting
<58>
F6-53
DeviceNet PPA setting
<58>
F6-54
DeviceNet Idle mode fault
<58>
detection
F6-56
DeviceNet Speed Scaling
<59>
Factor
F6-57
DeviceNet Current Scaling
<59>
Factor
F6-58
DeviceNet Torque Scaling
<59>
Factor
F6-59
DeviceNet Power Scaling
<59>
Factor
F6-60
DeviceNet Voltage Scaling
<59>
Factor
F6-61
DeviceNet Time Scaling
<59>
Factor
F6-62
DeviceNet Heartbeat Interval Sets the heartbeat interval for DeviceNet communications.
<59>
F7-01 Ethernet IP Address 1
F7-02 Ethernet IP Address 1
F7-03 Ethernet IP Address 1
F7-04 Ethernet IP Address 1
F7-05 Subnet Mask 1
F7-06 Subnet Mask 2
F7-07 Subnet Mask 3
F7-08 Subnet Mask 4
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
Description
Sets the node address for a PROFIBUS option.
Selects the operation when a "Clear Mode" command is
received.
0: Resets drive operation.
1: Maintains the previous operation state.
0: PPO Type
1: Conventional
0: Auto-adjust
1: 10 kbps
2: 20 kbps
3: 50 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1 Mbps
Sets the Node ID for a CompoNet option.
0: 93.75 kbps
1: Reserved
2: 1.5 Mbps
3: 3 Mbps
4: 4 Mbps
5-255: Reserved
Selects the drives MAC address for DeviceNet.
0: 125 kbps
1: 250 kbps
2: 500 kbps
3: Adjustable from Network
4: Detect automatically
I/O Polled Consuming Assembly Data Instance
I/O Polled Producing Assembly Data Instance
Selects if a EF0 fault is detected when no data are received
from the master.
0: Disabled
1: Enabled
Sets the scaling factor for the speed monitor in DeviceNet
Class ID 2AH Object.
Sets the scaling factor for the output current monitor in
DeviceNet Class ID 2AH Object.
Sets the scaling factor for the torque monitor in DeviceNet
Class ID 2AH Object.
Sets the scaling factor for the power monitor in DeviceNet
Class ID 2AH Object.
Sets the scaling factor for the voltage monitor in DeviceNet
Class ID 2AH Object.
Sets the scaling factor for the time monitor in DeviceNet
Class ID 2AH Object.
Combining these parameters like F7-01.F7-02.F7-03.F7-04
sets the Ethernet IP address. Example: (192.168.1.10).
Combining these parameters like F7-05.F7-06.F7-07.F7-08
sets the Ethernet Subnet Mask.
Example: (255.255.255.0).
B.2 Parameter Table
Control
Mode
Addr.
Range
Def.
OL
P
V/f
V
M
0 to 125
0
A A A
0 or 1
0
A A A
0 or 1
0
A A A
0 to 127
99
A A A
0 to 8
6
A A A
0 to 63
0
A A A
0 to 255
0
A A A
0 to 63
0
A A A
0 to 4
3
A A A
0 to 255
0
A A A
0 to 255
0
A A A
0 or 1
0
A A A
-15 to 15
0
A A A
-15 to 15
0
A A A
-15 to 15
0
A A A
-15 to 15
0
A A A
-15 to 15
0
A A A
-15 to 15
0
A A A
0 to 10
0
A A A
192
0 to 255
A A A
<60>
168
0 to 255
A A A
<60>
1
0 to 255
A A A
<60>
20
0 to 255
A A A
<60>
255
0 to 255
A A A
<60>
255
0 to 255
A A A
<60>
255
0 to 255
A A A
<60>
0 to 255
0
A A A
Pg.
Hex
3CB
156
3CC
156
3CD
156
3D0
156
3D1
156
3D5
156
3D6
157
3C1
157
3C2
157
3C3
157
3C4
157
3C5
157
3D7
157
3D8
157
3D9
157
3DA
157
3DB
157
3DC
157
3DD
158
3E5
158
3E6
158
3E7
158
3E8
158
3E9
158
3EA
158
B
3EB
158
3EC
158
313

Hide quick links: