Omron V1000 Product Information

Hide thumbs Also See for V1000:

Advertisement

VZ
V1000
More performance & Quality in less space
• Current vector control
• High starting torque (200% / 0.5 Hz)
• 1:100 speed control range
• Double rating ND 120%/1min and HD 150%/1 min
• IM&PM motor control
• Online Tuning
• Low-noise Low carrier technology
• 10 years lifetime design
• Built-in filter
• Screw-less terminals
• Control Terminals with memory backup
• 24 VDC control board power supply option
• Fieldbus communications: Modbus, Profibus, CanOpen,
DeviceNet, Lonworks, CompoNet, Ethernet, ML-II
• Safety embedded: EN954-1 safety cat. 3, EN6158 SIL II and
EN60204-1 Stop category 0
• CE, UL, cUL and TUV
Ratings
• 200 V Class single-phase 0.1 to 4 kW
• 200 V Class three-phase 0.1 to 15 kW
• 400 V Class three-phase 0.2 to 15 kW

System configuration

Power
Supply
MCCB
AC Reactor
Filter
V1000
Choke
Motor
Ground
V1000
RS232 Communications cable with PC
ni t
y U
C op
U SB
R
ER
C O
M
RJ-45 / USB
Adapter
C K
LO
A
AW
1
YA
SK
18
O P-
JV
Remote Operator
Extansion Cable
24Vdc Control Board Power Supply
Communication Option Board
Mounting Accesories
Braking Resistor
DC Reactor
CX-Drive
CX-One
USB Cable
LCD Remote
Operator
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron V1000

  • Page 1: System Configuration

    • 24 VDC control board power supply option • Fieldbus communications: Modbus, Profibus, CanOpen, DeviceNet, Lonworks, CompoNet, Ethernet, ML-II • Safety embedded: EN954-1 safety cat. 3, EN6158 SIL II and EN60204-1 Stop category 0 • CE, UL, cUL and TUV Ratings •...
  • Page 2: Specifications

    Allowable frequency fluctuation Only HD settings is available for this model Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overlaod capacity...
  • Page 3 Undervoltage (approx. 150 V or less for single-phase series) Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is Momentary power loss approx. 0.5 s or shorter, continuous operation...
  • Page 4 2015 0.37 40P2 0.55 40P4 40P7 137.5 41P5 42P2 Three-phase 43P0 400 V 44P0 45P5 47P5 4011 4015 V1000 + Option board (Communication and 24V DC power supply) Communication option boards PS-V10S PS-V10M 24V DC Power supply Options Frequency inverters...
  • Page 5 Built-in Filter Dimensions Dimensions in mm VZA@ B0P1 69.5 B0P2 B0P4 79.5 38.5 B0P7 77.9 59.6 137.5 B1P5 89.4 64.6 B2P2 96.4 66.6 B4P0 Under development 40P2 69.4 11.6 40P4 29.6 40P7 77.9 137.5 41P5 59.6 42P2 94.4 43P0 44P0 76.4...
  • Page 6 A1000-FIV1010-RE A1000-FIV1020-RE A1000-FIV1030-RE A1000-FIV1040-RE A1000-FIV3005-RE A1000-FIV3010-RE 3x400 V A1000-FIV3020-RE A1000-FIV3030-RE A1000-FIV3050-RE Remote LCD operator Installation holes (2-M3 screws, depth 5 (0.19)) 12.2 1.6 (0.06) (0.48) <1> 60 (2.36) 44 (1.73) (0.31) minimum 50 (1.96) Unit : mm (in) Chokes Description...
  • Page 7: Din Rail Mounting Bracket

    (common to all the units) EZZ08122D EZZ08122C Four, M4 tap Four, M4 tap Inverter VZA@ DIN rail mounting bracket 3-phase 200 VAC 20P1/ 20P2 / 20P4/ 20P7 EZZ08122A 21P5/ 22P2 EZZ08122B 24P0 EZZ08122C Single-phase 200 VAC B0P1/ B0P2/ B0P4 EZZ08122A...
  • Page 8 Heatsink attachment and Panel cut dimensions Heatsink External Mounting Attachment Mounting Panel D3 for more Fig 1 Fig 3 Fig 3 Fig 2 Fig 2 Fig 4 Fig 4 2 - 5 Dia. Holes 4-d Tap Frame Panel Cutting VZA@...
  • Page 9: Installation

    Cable Reverse/Stop Ground External Fault Fault Reset Multi-speed 1 Multi-speed 2 +24 V 8 mA Multi-function relay output 250 Vac / 30 VDC (10 mA to 1A) Fault Multi-function 24 V (default setting) digital inputs (default setting) SINK switch S3...
  • Page 10: Main Circuit

    Voltage input or current input Main Speed Freq Ref 0 to +10 VDC (20 kΩ) (resolution 1/1000) 4 to 20 mA (250 Ω) or 0 to 20 mA (250 Ω) Resolution: 1/500 Frequency reference common +24 V (max allowable current 10 mA)
  • Page 11: Inverter Heat Loss

    Space required differs by model: Up to 3.7 kW: minimum 30 mm 5.5 kW and above: minimum 50 mm At least 100 mm Airflow At least 100 mm Side by Side mounting Inverter heat loss Three-phase 200 V class...
  • Page 12 Connections for braking resistor Thermal relay Braking resistor Power supply MCCB R/L1 B1 S/L2 U/T1 T/L3 Motor V/T2 W/T3 THRX THRX Thermal relay switch for external braking resistor FLT-A FLT-B Fault contact AC reactor AC reactor Power supply MCCB R/L1...
  • Page 13: Safety System

    Safety System V1000...
  • Page 14: Ordering Information

    Ordering information Power Supply RS232 Communications cable with PC MCCB ni t C op U SB RJ-45 / USB USB Cable CX-Drive Adapter AC Reactor CX-One O P- Remote Operator LCD Remote Extansion Cable Operator Filter 24Vdc Control Board Power Supply...
  • Page 15 B Communication cards Type Model Description Function • Used for running or stopping the inverter, setting or referencing parameters, and monitoring SI-N3/V-OY DeviceNet option card output frequency, output current, or similar items through DeviceNet communication with the host controller. • Used for running or stopping the inverter, setting or referencing parameters, and monitoring...
  • Page 16 4015 A1000-REV04K0032-IE Mounting accesories Types Model Description Applicable models VZA@ 20P1/20P2/20P4/20P7 EZZ08122A B0P1/B0P2/B0P4 21P5/22P2 EZZ08122B B0P7/B1P5 40P2/40P4/40P7/41P5/42P2 Necessary to mount the inverter on a DIN rail 24P0 EZZ08122C B2P2 44P0 EZZ08122D B4P0 20P1/20P2 100-034-075 B0P1/B0P2 20P4 100-034-076 B0P4 100-034-077 20P7...
  • Page 17 V1000...
  • Page 18 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. I68E-EN-02 Frequency inverters...

This manual is also suitable for:

V1000 vza series

Table of Contents