Omron V1000 User Manual page 302

Compact vector control drive 200 v class three-phase input 0.1 to 15 kw, 200 v class single-phase input 0.1 to 4.0 kw, 400 v class three-phase input 0.2 to 15 kw
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
Name
Short Circuit Brake Time at
b2-12
Start
Short Circuit Brake Time at
b2-13
Stop
b3-01
Speed Search Selection
Speed Search Deactivation
b3-02
Current
Speed Search Deceleration
b3-03
Time
b3-05
Speed Search Delay Time
Output Current 1 during
b3-06
Speed Search
Speed Search Detection
b3-10
Compensation Gain
Bi-Directional Speed Search
b3-14
Selection
Speed Search Restart Current
b3-17
Level
Speed Search Restart
b3-18
Detection Time
Number of Speed Search
b3-19
Restarts
Speed Search Method
b3-24
Selection
Speed Search Retry Interval
b3-25
Time
Timer Function On-Delay
b4-01
Time
Timer Function Off-Delay
b4-02
Time
b5-01
PID Function Setting
b5-02
Proportional Gain Setting
<22>
(P)
b5-03
Integral Time Setting (I)
<22>
b5-04
Integral Limit Setting
<22>
b5-05
Derivative Time (D)
<22>
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
Description
Sets the time for Short-Circuit brake operation at start.
Disabled when set to 0.00.
<32>
Sets the Short-Circuit brake operation time at stop. Used to
stop a motor rotating due to inertia. Disabled when set to 0.00
seconds.
<32>
b3: Speed Search
Use b3 parameters to configure Speed Search function operation.
Enables/disables the Speed Search function at start.
0: Disabled - Speed Search is not automatically performed at
start.
1: Enabled - Speed Search is automatically performed at start.
Sets the current level at which the speed is assumed to be
detected and Speed Search is ended. Set as a percentage of
the drive rated current.
Sets the time constant used to reduce the output frequency
during Speed Search. Related to a change from max. output
frequency to 0.
Delays the Speed Search operation after a momentary power
loss to allow time for an external output contactor to close. 0.0 to 100 0.2 s A A A
Sets the current injected to the motor at the beginning of
Estimation type Speed Search. Set as a factor of the motor
rated current.
Sets the gain which is applied to the speed detected by Speed
Estimation Speed Search before the motor is reaccelerated.
Increase this setting if ov occurs when performing Speed
Search.
Selects if Speed Search detects the motor rotation direction
during Speed Search.
0: Disabled–Frequency reference direction used
1: Enabled–Detected direction used
Sets the Speed Search restart current level as a percentage of
the drive rated current.
Sets the time in seconds for Speed Search restart to be
detected.
Sets the number of restarts possible for Speed Search restart
operations.
Sets the Speed Search detection mode.
0: Current Detection Type
1: Speed Estimation Type
Sets the wait time before Speed Search restarts.
b4: Timer Function
Use b4 parameters to configure timer function operation.
Used in conjunction with a multi-function digital input (H1-
 = 18) and a multi-function digital output (H2- = 12)
programmed for the timer function. This sets the amount of
time between digital input closure and digital output
activation.
Used in conjunction with a multi-function digital input (H1-
 = 18) and a multi-function digital output programmed
for the timer function. This sets the amount of time the output
remains activated after the digital input is opened.
b5: PID Control
Use b5 parameters to configure the PID control drive function.
Sets the PID control mode.
0: Disabled
1: Enable (PID output = freq. ref., PID input is D-controlled)
2: (PID output = freq. ref., PID feedback is D-controlled)
3: Enable (PID output added to freq. ref., PID input is D-
controlled)
4: Enable (PID output added to freq. ref., PID feedback is D-
controlled)
Sets the proportional gain of the PID controller. A setting of
0.00 disables P control.
Sets the integral time for the PID controller. A setting of 0.0
s disables integral control.
Sets the maximum output possible from the integrator.
Sets D control derivative time. A setting of 0.00 s disables
derivative control.
B.2 Parameter Table
Control
Mode
Addr.
Range
Def.
O
P
V/f
LV
M
0.00 to
0.00 s −
− A
25.50
0.00 to
0.50 s −
− A
25.50
0 to 1
0
A A A
120
0 to 200
A A −
<2>
0.1 to 10.0 2.0 s A A −
0.0 to 2.0
<12>
A A −
1.00 to
1.05 A A −
1.20
0,1
0
A A −
0 to 200 150% A A −
0.00 to
0.10 s A A −
1.00
0 to 10
3
A A −
0,1
0
A A −
0 to 30.0 0.5 s A A A
0.0 to
0.0 s A A A
300.0
0.0 to
0.0 s A A A
300.0
0 to 4
0
A A A
0.00 to
1.00 A A A
25.00
0.0 to
1.0 s A A A
360.0
0.0 to
100.0
A A A
100.0
%
0.00 to
0.00 s A A A
10.00
Pg.
Hex
1BA
110
1BB
110
191
113
192
113
193
113
195
113
196
114
19A
114
19E
114
1F0
114
1F1
114
1F2
114
1C0
114
1C8
115
1A3
115
1A4
115
1A5
118
1A6
118
1A7
118
B
1A8
118
1A9
118
301