D.2 European Standards
Drive
VZA
Type
40P2
A1000–FIV3005–SE
40P4
A1000–FIV3005–SE
40P7
A1000–FIV3005–SE
41P5
A1000–FIV3010–SE
42P2
A1000–FIV3010–SE
43P0
A1000–FIV3010–SE
44P0
A1000–FIV3020–SE
45P5
A1000–FIV3030–SE
47P5
A1000–FIV3030–SE
4011
A1000–FIV3050–SE
4015
A1000–FIV3050–SE
Note: Use filters manufactured by Rasmi as listed below only if the Safe Disable function of the drive is not part of the safety concept of a
machine or installation and not used for a safe stop according to EN60204-1, stop category 0. If the Safe Disable function of the drive is
part of the safety concept of a machine or installation, use filters manufactured by Schaffner as listed above.
Drive VZA
Type
B0P1
A1000–FIV1010–RE
B0P2
A1000–FIV1010–RE
B0P4
A1000–FIV1010–RE
B0P7
A1000–FIV1020–RE
B1P5
A1000–FIV1020–RE
B2P2
A1000–FIV1030–RE
B4P0
A1000–FIV1040–RE
20P1
A1000–FIV2010–RE
20P2
A1000–FIV2010–RE
20P4
A1000–FIV2010–RE
20P7
A1000–FIV2010–RE
21P5
A1000–FIV2020–RE
22P2
A1000–FIV2020–RE
24P0
A1000–FIV2030–RE
25P5
A1000–FIV2060–RE
27P5
A1000–FIV2060–RE
2011
A1000–FIV2080–RE
2015
A1000–FIV2100–RE
40P2
A1000–FIV3005–RE
40P4
A1000–FIV3005–RE
40P7
A1000–FIV3005–RE
41P5
A1000–FIV3010–RE
42P2
A1000–FIV3010–RE
43P0
A1000–FIV3010–RE
44P0
A1000–FIV3020–RE
45P5
A1000–FIV3030–RE
47P5
A1000–FIV3030–RE
4011
A1000–FIV3050–RE
4015
A1000–FIV3050–RE
386
Filter Data (Manufacturer: Schaffner)
Rated
Weight
Dimensions
Current
(kg)
[W x L x H] (mm)
(A)
400 V Three-Phase Units
5
0.5
111 x 169 x 45
5
0.5
111 x 169 x 45
5
0.5
111 x 169 x 45
10
0.7
111 x 169 x 45
10
0.7
111 x 169 x 45
10
0.7
111 x 169 x 45
15
0.9
144 x 174 x 50
30
1.8
137 x 304 x 56
30
1.8
137 x 304 x 56
50
2.7
175 x 340 x 65
50
2.7
175 x 340 x 65
Table D.3 EN 61800-3 Category C1 Filters
Filter Data (Manufacturer: Rasmi)
Rated
Weight
Dimensions
Current
(kg)
[W x L x H]
(A)
200 V Single-Phase Units
10
0.6
71 x 169 x 45
10
0.6
71 x 169 x 45
10
0.6
71 x 169 x 45
20
1.0
111 x 169 x 50
20
1.0
111 x 169 x 50
30
1.1
144 x 174 x 50
40
1.2
174 x 174 x 50
200 V Three-Phase Units
10
0.8
82 x 194 x 50
10
0.8
82 x 194 x 50
10
0.8
82 x 194 x 50
10
0.8
82 x 194 x 50
16
1.0
111 x 169 x 50
16
1.0
111 x 169 x 50
26
1.3
144 x 174 x 50
58
2.4
150 x 320 x 52
58
2.4
150 x 320 x 52
78
4.2
188 x 362 x 62
96
4.4
220 x 415 x 62
400 V Three-Phase Units
5
1.0
111 x 169 x 45
5
1.0
111 x 169 x 45
5
1.0
111 x 169 x 45
10
1.0
111 x 169 x 45
10
1.0
111 x 169 x 45
10
1.0
111 x 169 x 45
15
1.1
144 x 174 x 50
29
2.0
150 x 306 x 52
29
2.0
150 x 306 x 52
48
2.8
175 x 357 x 62
48
2.8
175 x 357 x 62
Drive
Y x X
Mounting
Screw A
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
120 x 161
M4
100 x 289
M5
100 x 289
M5
130 x 325
M5
130 x 325
M5
Drive
Y x X
Mounting
Screw A
51 x 156
M4
51 x 156
M4
51 x 156
M4
91 x 156
M4
91 x 156
M4
120 x 161
M4
150 x 161
M4
62 x 181
M4
62 x 181
M4
62 x 181
M4
62 x 181
M4
91 x 156
M4
91 x 156
M4
120 x 161
M4
122 x 290
M5
122 x 290
M5
160 x 330
M5
192 x 380
M6
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
91 x 156
M4
120 x 161
M4
122 x 290
M5
122 x 290
M5
160 x 330
M5
160 x 330
M5
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
Filter
Mounting
Screw
M5
M5
M5
M5
M5
M5
M5
M5
M5
M6
M6
Filter
Mounting
Screw
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M5
M6
M6
M5
M5
M5
M5
M5
M5
M5
M5
M5
M6
M6

Hide quick links: