Operating Procedure; Setting The Operation Mode - Omron E3X-DA-S Series Manual

Advanced fiber amplifier units
Hide thumbs Also See for E3X-DA-S Series:
Table of Contents

Advertisement

E3X-DA-S
Nomenclature
Fiber Amplifier Units
E3X-DA@-S (@: 21/51/7/9/0)
Main Display (Red)
Sub-Display (Green)
Incident level, function, etc.
Threshold, function settings,
etc.
Lock lever
Locks the fiber unit.
Operation Indicator
Operation Indicator
(ch2) (orange)
(ch1) (orange)
ON when output is ON.
ON when output is ON.
OFF when output is OFF.
OFF when output is OFF.

Operating Procedure

1

Setting the Operation Mode

The operation mode is set in SET Mode.
➜Refer to 5. Setting Functions on page 20.
Set the Channel Selector Switch to the desired channel
before making any adjustments or settings.
2
Adjusting the Power (RUN Mode)
The current incident light level can be adjusted near the
power tuning target value (default: 2,000).
✽ Confirm that the MODE Key setting is PTUN (power tuning). The
default setting is PTUN.
➜Refer to 5. Setting Functions on page 20.
✽ If power tuning is executed while SHS is selected for the detection
function, the minimum power will be set.
Set the SET/RUN Mode
Selector Switch to RUN.
RUN
(Factory-set to RUN)
Release the key after
the progress bar is
displayed.
Display changes after
specific time.
This completes the
adjustment.
18
Operation Keys
Function setting
UP
operations
DOWN
MODE
Channel Selector
Use to select the channel to display and set.
Mode Selector
Use to select SET or RUN Mode.
Incident level
Threshold (default)
MODE
3 s
PTUN
Progress bar
Power tuning
target value
Incident level
Threshold
Note: Nomenclature and operating procedures for the E3X-
DA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on
pages 19 and 20.
To restore the default
power setting:
✽ Press the DOWN Key
right after pressing
the MODE Key.
"OFF" will flash twice.
This restores the default
setting.
✽ Setting Errors
An error has occurred if one of the following displays appears after
the progress bar is displayed.
Display
Flashes twice
PTUN
OVER
Flashes twice
PTUN
BOTM
3
Setting Thresholds Manually (RUN Mode)
A threshold can be set manually. A threshold can also
be adjusted manually after teaching to fine-tune it.
Set the Mode Selector
Switch to RUN.
RUN
(Factory-set to RUN)
Increases threshold.
✽ Even if the display method is changed, the threshold will appear
on the sub-display when the key is pressed.
DOWN
Press
MODE
both
for 3 s.
PTUN
OFF
Incident level
Threshold
Error
Action
Over Error
The power will not
be tuned. The power
The incident light
can be increased up
level is too low
to approximately 5
for the power
times the incident
tuning target
light value.
value.
Bottom Error
The power will be
turned to the
The incident light
minimum level. The
level is too high
power can be
for the power
decreased down to
tuning target
approximately
value.
1/20th the incident
light value.
Light level
Threshold (default)
UP
DOWN
Decreases threshold.