SECTION 3
Preparing for Communications
Set the Communications Conditions for the CIDRW
Controller
Set the communications conditions of the CIDRW Controller only when SECS is used.
1
Switch to the
Setting mode
7
Set Software
Revisions

Switch to the Setting mode

The CIDRW Controller has two operating modes, the Normal Operation mode and the Setting mode.
Switch to the Setting mode to set the communications conditions.
There are two methods for switching the mode. Use the one that is appropriate for the circumstances.
■ Changing the Position of the Mode Switch on the Bottom of the Unit
This is the convenient method for setting before mounting the unit.
1.
Turn OFF the power to the CIDRW Controller.
2.
Set the mode switch on the bottom of the unit to
3.
CIDRW System
48
User's Manual
2
3
Start the
Set the
terminal
parameters for the
software
communications
conditions.
8
Return to the
Normal
Operation
mode
4
5
Change the
Change the
Carrier ID
data segment
area
6
Change the
response
time-out time

Advertisement