Types of Alarms, Faults, and Errors

Check the LED operator for information about possible faults if the drive or motor fails to operate.
Digital LED Operator on page
If problems occur that are not covered in this manual, contact the nearest OYMC representative with the following
information:
• Drive model
• Software version
• Date of purchase
• Description of the problem
Table 6.4
contains descriptions of the various types of alarms, faults, and errors that may occur while operating the drive.
Type
When the drive detects a fault:
• The digital operator displays text that indicates the specific fault and the ALM indicator LED remains lit until the fault
is reset.
• The fault interrupts drive output and the motor coasts to a stop.
Faults
• Depending on the setting, the drive and motor may stop via different methods than listed.
• If a digital output is programmed for fault output (H2- = E), it will close if a fault occurs.
When the drive detects a fault, it will remain inoperable until that fault has been reset.
page
252.
When the drive detects an alarm or a minor fault:
• The digital operator displays text that indicates the specific alarm or minor fault and the ALM indicator LED flashes.
Minor Faults and
• The motor does not stop.
Alarms
• One of the multi-function contact outputs closes if set to be tripped by a minor fault (H2- = 10), but not by an alarm.
• The digital operator displays text indicating a specific alarm and ALM indicator LED flashes.
Remove the cause of an alarm or minor fault to automatically reset.
When parameter settings conflict with one another or do not match hardware settings (such as with an option card), it results
in an operation error.
When the drive detects an operation error:
Operation Errors
• The digital operator displays text that indicates the specific error.
• Multi-function contact outputs do not operate.
When the drive detects an operation error, it will not operate the motor until the error has been reset. Correct the settings
that caused the operation error to reset.
Tuning errors occur while performing Auto-Tuning.
When the drive detects a tuning error:
• The digital operator displays text indicating the specific error.
Tuning Errors
• Multi-function contact outputs do not operate.
• Motor coasts to stop.
• Remove the cause of the error and repeat the Auto-Tuning process.
u

Alarm and Error Displays

n
Faults
When the drive detects a fault, the ALM indicator LEDs remain lit without flashing. If the LEDs flash, the drive has
detected a minor fault or alarm.
as overvoltage or external faults can trip both faults and minor faults, therefore it is important to note whether the LEDs
remain lit or if the LEDs flash.
LED Operator
Display
bUS
Option Communication Error
MEMOBUS/Modbus
CE
Communication Error
CF
Control Fault
CoF
Current Offset Fault
CPF02 A/D Conversion Error
CPF03 PWM Data Fault
Drive specification mismatch during
CPF06
Terminal Board or Control Board
replacement
Terminal Board Communication
CPF07
Fault
EEPROM Serial Communications
CPF08
Fault
CPF11 RAM Fault
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
66.
Table 6.4 Types of Alarms, Faults, and Errors
Drive Responses to Alarms, Faults, and Errors
Refer to Minor Faults and Alarms on page 228
Table 6.5 Fault Displays
Name
Page
230
230
230
230
230
231
231
231
231
231

6.3 Drive Alarms, Faults, and Errors

for more information. Conditions such
LED Operator
Display
CPF12 FLASH Memory Fault
CPF13 Watchdog Circuit Exception
CPF14 Control Circuit Fault
CPF16 Clock Fault
CPF17 Timing Fault
CPF18 Control Circuit Fault
CPF19 Control Circuit Fault
RAM Fault
CPF20 or
FLASH Memory Fault
or
CPF21
Watchdog Circuit Exception
<1>
Clock Fault
CPF22 A/D Conversion Error
CPF23 PWM Feedback Data Fault
Refer to Using the
Refer to Fault Reset Methods on
Name
Page
231
231
231
231
231
231
231
232
232
232
232
232
232
227