Three-Phase 400 V Class Drives; Three-Phase 400 V Class Drives - Omron V1000 User Manual

Compact vector control drive 200 v class three-phase input 0.1 to 15 kw, 200 v class single-phase input 0.1 to 4.0 kw, 400 v class three-phase input 0.2 to 15 kw
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

A.3 Three-Phase 400 V Class Drives
Maximum Applicable Motor Capacity (kW)
Input
Input Current (A)
Output Current (kVA)
Output Current (A)
Output
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
Rated Voltage Rated Frequency
Power Supply
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Harmonic Corrective Actions
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater
than the motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 440 V.
<4> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency is set to Swing PWM. Current derating is required in order to raise the carrier frequency.
Maximum Applicable Motor Capacity
<1>
(kW)
Input
Input Current (A)
Output Current (kVA)
Output Current (A)
Output
Overload Tolerance
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
Rated Voltage Rated Frequency
Power
Allowable Voltage Fluctuation
Supply
Allowable Frequency Fluctuation
Harmonic Corrective Actions
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater
than the motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 440 V.
<4> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency is set to Swing PWM. Current derating is required in order to raise the carrier frequency.
Note: Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated input and output current, overload
capacity, carrier frequency and current limit. Set parameter C6-01 to "0" (default) for HD or "1" for ND.
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
Table A.4 Power Ratings
Item
VZA
HD Rating
<1>
ND Rating
HD Rating
<2>
ND Rating
HD Rating
<3>
ND Rating
HD Rating
ND Rating
Overload Tolerance
Carrier Frequency
DC Reactor
Table A.5 Power Ratings Continued
Item
VZA
HD Rating
ND Rating
HD Rating
<2>
ND Rating
<4>
HD Rating
<3>
<5>
ND Rating
<4>
HD Rating
<5>
ND Rating
Carrier Frequency
DC Reactor
A.3 Three-Phase 400 V Class Drives
40P2
40P4
0.2
0.4
0.4
0.75
1.2
1.8
1.2
2.1
<4>
0.9
1.4
<5>
0.9
1.6
<4>
1.2
1.8
<5>
1.2
2.1
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop
User adjustable between 2 and 15 kHz (see HD output current line of
this table for default values)
Three-phase: 380 to 480 V (proportional to input voltage)
400 Hz (user-adjustable)
Three-phase: 380 to 480 V 50/60 Hz
Specification
45P5
47P5
5.5
7.5
7.5
11.0
15.0
20.0
20.0
24.0
11.3
13.7
13.3
17.5
14.8
18.0
17.5
23.0
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
User adjustable between 2 and 15 kHz (see HD output current line of this
table for default values)
Three-phase: 380 to 480 V (proportional to input voltage)
400 Hz (user-adjustable)
Three-phase: 380 to 480 V 50/60 Hz
Specification
40P7
41P5
42P2 43P0
0.75
1.5
2.2
3.0
1.5
2.2
3.0
3.7
3.2
4.4
6.0
8.2
4.3
5.9
8.1
9.4
2.6
3.7
4.2
5.5
3.1
4.1
5.3
6.7
3.4
4.8
5.5
7.2
4.1
5.4
6.9
8.8
frequently)
-15 to 10%
±5%
Optional
4011
11.0
15.0
29.0
38.0
18.3
23.6
24.0
31.0
-15 to 10%
±5%
Optional
44P0
4.0
5.5
10.4
14.0
7.0
8.5
9.2
11.1
4015
15.0
18.5
39.0
44.0
23.6
29.0
31.0
38.0
A
291

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents