Hide thumbs Also See for V640 Series:

Advertisement

Quick Links

CIDRW SYSTEM
V640 SERIES
USER'S MANUAL
AMPLIFIER UNITS
V640-HAM11-ETN-V2
V640-HAM11-L-ETN-V2
CIDRW HEADS
V640-HS61
V640-HS62
Man. No. Z361-E1-03

Advertisement

Table of Contents
loading

Summary of Contents for Omron V640 Series

  • Page 1 CIDRW SYSTEM V640 SERIES USER'S MANUAL AMPLIFIER UNITS V640-HAM11-ETN-V2 V640-HAM11-L-ETN-V2 CIDRW HEADS V640-HS61 V640-HS62 Man. No. Z361-E1-03...
  • Page 2 Introduction Thank you for purchasing the V640-series CIDRW System. Please observe the following points when operating the V640-series CIDRW System: • Allow the CIDRW System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. •...
  • Page 3 Table of Contents/Precautions in Using the Products Introduction SECTION 1 Product Outline Installation and Connections/Wiring SECTION 2 SECTION 3 Preparing for Communications Reading from/Writing to ID Tags SECTION 4 SECTION 5 Browser Interface Troubleshooting SECTION 6 SECTION 7 Appendix CIDRW System V640-HAM11-ETN-V2 Amplifier Unit V640-HAM11-L-ETN-V2...
  • Page 4 PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
  • Page 5 Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements.
  • Page 6 INTRODUCTION Safety Precautions l Definition of Precautionary Information The following notation and alert symbols are used in this User's Manual to provide precautions required to ensure safe usage of a V640-series CIDRW System. The safety precautions that are provided are extremely important to safety.
  • Page 7 INTRODUCTION Precautions for Safe Use Please observe the following precautions for safe use of the products. • Never use the product in an environment where combustible or explosivegas is present. • Please separate from a high-pressure equipment and the power equipment to secure the safety of the operation and maintenance.
  • Page 8 INTRODUCTION Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunctions, or undesirable effects on product performance. ■ About installation Site Do not install this product in the locations subject to the following conditions. • Place where direct sunshine strikes. •...
  • Page 9 INTRODUCTION ■ About mounting • This product communicates with ID Tags using the 134 kHZ frequency band. Some transceivers, motors, monitoring equipment, and power supplies (power supply ICs) generate electrical waves (noise) that interfere with communications with ID Tags, If you are using the product in the vicinity of any of these devices, check the effect on communications in advance.
  • Page 10 INTRODUCTION Reading this Manual Visual Aids Indicates an explanation of a point that must be observed to ensure that the product is capable of its proper functions and perfor- mance. Read this information carefully and follow the cautions. If the product is used incorrectly, data or the equipment itself could be destroyed.
  • Page 11 INTRODUCTION Table of Contents Table of Contents Introduction Safety Precautions Precautions for Safe Use Precautions for Correct Use Reading this Manual Table of Contents SECTION 1 Product Outline What Is a CIDRW System Features System Configuration Component Names and Functions Flowchart for Getting Started SECTION 2 Installation and Connections/Wiring Installation...
  • Page 12: Table Of Contents

    INTRODUCTION Table of Contents Troubleshooting SECTION 7 Appendix Specifications and Dimensions Connection Examples Characteristic Data According to Conditions of Use ID Tag Memory Maps Regular Inspection ASCII Code Table Protective Construction SECTION 8 Revision History CIDRW System User’s Manual...
  • Page 13 SECTION 1 Product Outline What Is a CIDRW System Features System Configuration Component Names and Functions Flowchart for Getting Started CIDRW System User’s Manual...
  • Page 14: What Is A Cidrw System

    ID Tag (holder is separate) CIDRW Head Reading and writing information • Model information • Process instruction information • Completion information • Lot information Amplifier Unit • Inspection results Etc. Ethernet hub Recommended: W4S1-05B (OMRON) Host CIDRW System User’s Manual...
  • Page 15: Features

    SECTION 1 Product Outline Features A V640-series CIDRW Head can be connected to a V640-HAM11-ETN-V2 or V640-HAM11-L-ETN-V2 Amplifier Unit to read and write ID Tags manufactured by Texas Instruments (TI). Reading and writing is performed according to commands from the host device. ■...
  • Page 16: System Configuration

    SECTION 1 Product Outline System Configuration V640-HAM11-ETN-V2 Ethernet hub Host device Recommended: W4S1-05B(OMRON) CIDRW Head Amplifier Unit V640-HS61 V640-HAM11-ETN-V2 LAN cable LAN cable V640-HAM11-L-ETN-V2 Ethernet hub Host device Recommended: W4S1-05B(OMRON) Amplifier Unit CIDRW Head V640-HAM11-L-ETN-V2 V640-HS62 LAN cable LAN cable If the IP address is set on the DIP switch, it will be in the form 192.168.1.@@@.
  • Page 17: Component Names And Functions

    SECTION 1 Product Outline Component Names and Functions V640-HAM11-ETN-V2 and V640-HAM11-L-ETN-V2 Amplifier Units Name Function Dedicated power supply con- Connect to the 24 VDC power supply. nector Ethernet port Connect to the host device through a LAN cable. RUN indicator (green) Turns ON when the Amplifier Unit is in normal operation.
  • Page 18 SECTION 1 Product Outline ■ Functions • NOISE MEASUREMENT The levels of noise in the vicinity of the CIDRW Head are measured and the noise level is expressed numerically in the range "00" to "99. Refer to page 47, page 110. •...
  • Page 19 SECTION 1 Product Outline V640-HS61 and V640-HS62 CIDRW Heads ■ V640-HS61 Name Function Antenna Used to communicate with ID Tags. Antenna center This is the center of the communications area. Connector Connect to an Amplifier Unit. ■ V640-HS62 V640-HS62 CIDRW HEAD MADE IN JAPAN Name Function...
  • Page 20: Flowchart For Getting Started

    SECTION 1 Product Outline Flowchart for Getting Started Installation Refer to page 22. Connection and Wiring Refer to page 25. Setting the Communications Conditions for Amplifier Units Refer to page 30. Test for Communications with the Host Device Refer to page 31. ID Tag <->...
  • Page 21 SECTION 1 Product Outline Communications Test with Actual Commands Refer to page 34. When you Encounter a Problem... Troubleshooting Refer to page 68. List of Error Messages Refer to page 68. Amplifier Unit Indicators Refer to page 69. Operation Check Flowchart CIDRW System User’s Manual...
  • Page 22 SECTION 1 Product Outline MEMO CIDRW System User’s Manual...
  • Page 23 SECTION 2 Installation and Connections/Wiring Installation Amplifier Unit CIDRW Head Connections and Wiring Amplifier Unit CIDRW System User’s Manual...
  • Page 24: Installation

    SECTION 2 Installation and Connections/Wiring Installation Amplifier Unit Use spring washers and flat washers with the four M4 screws when mounting the Amplifier Unit. Mounting dimensions (Unit: mm) 175±0.5 4-M4 Tighten the M4 screws with a torque not exceeding 1.2 N·m. CIDRW System User’s Manual...
  • Page 25: Cidrw Head

    SECTION 2 Installation and Connections/Wiring CIDRW Head The area for communications with ID Tags varies substantially according to the installation orientations and the background conditions (metals, noise, etc.). Check the communications area before deciding the installation position. For details on actual communications distances, see Characteristic Data depending on Conditions of Use in Appendix.
  • Page 26 SECTION 2 Installation and Connections/Wiring ■ Influence of Background Metal on ID Tag Metals in the vicinity of the communications area will affect the range, making it smaller. Refer to page 106. ■ Influence of Noise This CIDRW system uses a frequency of 134 kHz for communications with ID Tags. Equipment such as switching power supplies, inverters, servomotors, or monitors in the surrounding area will adversely affect communications, restricting the communications area.
  • Page 27: Connections And Wiring

    SECTION 2 Installation and Connections/Wiring Connections and Wiring Amplifier Unit ■ Connector for Connecting a CIDRW Head Align the pin on the connector with the channel in the cable connector and insert the cable connector. Hold the fixed part of the connector while making this insertion.
  • Page 28 5110:1996) To prevent faulty connections for connectors, the jack on the Amplifier Unit is designed so that non-standard plugs cannot be connected. If a commercially available plug cannot be connected, it may be non-standard. If you use a Hub in your network, please choose a Switching-type Hub (Recommended: W4S1-05B(OMRON)). CIDRW System...
  • Page 29 Recommended Product Manufacturer Model Output current Input voltage OMRON S8VS-01524 24 VDC, 650 mA 100 to 240 VAC *The maximum power consumption of the Amplifier Unit is 150 mA at 24 VDC(V640-HAM11-V3), 400 mA at 24 VDC(V640-HAM11-L). The inrush current, however, must be considered when selecting the power supply capacity.
  • Page 30 SECTION 2 Installation and Connections/Wiring MEMO CIDRW System User’s Manual...
  • Page 31 SECTION 3 Preparing for Communications Setting the Communications Conditions for Amplifier Units Communications Test CIDRW System User’s Manual...
  • Page 32 SECTION 3 Preparing for Communications Setting the Communications Conditions for Amplifier Units Set the communications conditions using the DIP switches on the side face of the Amplifier Unit. After changing the DIP switch settings, restart the system. The new settings will not become effective until the system is restarted.
  • Page 33 SECTION 3 Preparing for Communications Communications Test Communications Test with the Host Device A communications test is performed to confirm that the host device and Amplifier Unit are connected correctly. Refer to Host Communications Specifications. Refer to page 77. Amplifier Unit Host A test is preformed for the Amplifier Unit using the data 12345678.
  • Page 34 SECTION 3 Preparing for Communications Communications Test between ID Tags and CIDRW System Send a command from the host device and check that normal communications with the ID Tag is pos- sible. Place an ID Tag in the communications area of the CIDRW Head connected to the Amplifier Unit for which communications is to be tested.
  • Page 35 SECTION 4 Reading from/Writing to ID Tags Command/Response Format READ WRITE SAME WRITE BYTE WRITE TEST GET PARAMETER GET LAST COMMAND GET COMMUNICATIONS HISTORY CLEAR COMMUNICATIONS HISTORY NOISE MEASUREMENT RESET SET WEB PASSWORD SET NETWORK CIDRW System User’s Manual...
  • Page 36: Command/Response Format

    SECTION 4 Reading from/Writing to ID Tags Command/Response Format Command Parameter Command code ⋅ ⋅ ⋅ Response Parameter Response code ⋅ ⋅ ⋅ Command Command Code List Name Value Function READ 0100 When this command is received, the system communicates with the ID Tag, and p.35 reads the specified page(s) of data.
  • Page 37: Read

    SECTION 4 Reading from/Writing to ID Tags Response Code List Response Type Name Description code Normal end Normal end Command execution is completed normally. Host commu- Format error There is a mistake in the command format. (For example, the command nications error code is undefined, or the page or address specification is inappropriate.) Communica-...
  • Page 38: Write

    SECTION 4 Reading from/Writing to ID Tags Example: Reading Data from Pages 1 and 3 of the Amplifier Unit. Data Content of the ID Tag Page 1 Page 2 Page 3 Page 4 Command Command code Page designation Binary notation Response Response Page 1...
  • Page 39 SECTION 4 Reading from/Writing to ID Tags Parameter Description Parameter Description Page designation Pages are specified by setting the bits corresponding to pages that are to be read to 1 and setting the other bits to 0, then converting the result to a hexadecimal character string. Write data The data to be written to the specified pages is specified in ascending order of page numbers.
  • Page 40: Same Write

    SECTION 4 Reading from/Writing to ID Tags ■ SAME WRITE This command writes the same data to multiple pages of an ID Tag. Any page(s) can be specified. Command Write data Command code Page designation (8 characters) Data 1 ⋅ ⋅ ⋅ Data 8 Page Sys Sys...
  • Page 41: Byte Write

    SECTION 4 Reading from/Writing to ID Tags ■ BYTE WRITE This command writes data to any specified number of bytes starting from the address specified in the ID Tag. The maximum number of bytes that can be written at one time is 128. Command Write data First...
  • Page 42: Test

    SECTION 4 Reading from/Writing to ID Tags ■ TEST Performs a communications test on communications between the host device and Amplifier Unit. When an Amplifier Unit receives a test command, it sends the response code and command test data to the host device as the response. Command Test data Command code...
  • Page 43: Nak

    SECTION 4 Reading from/Writing to ID Tags ■ NAK Sends the response made immediately before again. Command Command code Response Sends the response made immediately before again. A response will not be returned if a NAK command is executed immediately after startup. ■...
  • Page 44 SECTION 4 Reading from/Writing to ID Tags Example 1: Getting the Model Number of Amplifier Unit Command Parameter Command code type Response The product model number is returned as an ASCII text string. Response Model number code Example 2: Getting the Firmware Version of Amplifier Unit Command Parameter Command code...
  • Page 45 SECTION 4 Reading from/Writing to ID Tags Response The response code (00: normal) and MAC address are returned. Response code MAC address * The above response is for a MAC address of 00:1F:16:1A:B9:8E. Example 4: Checking If Network Settings on DIP Switch on Amplifier Unit Are Enabled or Disabled Command Parameter Command code...
  • Page 46 SECTION 4 Reading from/Writing to ID Tags Example 6: Checking the Subnet Mask on the DIP Switch of Amplifier Unit Command Parameter Command code type Response The response code (00: normal) and subnet mask (decimal, four octets of 3 digits each) are returned. Response code Subnet mask on DIP switch Second octet...
  • Page 47 SECTION 4 Reading from/Writing to ID Tags Example 9: Getting the Memory Status of Amplifier Unit Command Parameter Command code type Response The response code (00: normal) and memory check results for internal EEPROM are returned. Response Memory status code * “Memory status”...
  • Page 48: Get Last Command

    SECTION 4 Reading from/Writing to ID Tags ■ GET LAST COMMAND Gets the command code of the last command that was executed. Command Command code Response This command returns the command code of the last command that was executed. When There Is a Previously Executed Command Response Command code code...
  • Page 49: Clear Communications History

    SECTION 4 Reading from/Writing to ID Tags Example 1: Getting the Communications History of Amplifier Unit Command Command code Response The following response is returned if there are 32,000 total communications, 30,000 successful communications, and 2,000 failed communications. Total number of suc- Response Total number of com- Total number of failed...
  • Page 50: Reset

    SECTION 4 Reading from/Writing to ID Tags ■ RESET All Amplifier Unit processing is stopped, and the initial status is re-established. Command Command code Response There is no response to this command. ■ SET WEB PASSWORD This command sets the Web password. If you set a password, a Password entry window will be displayed when you start the browser window.
  • Page 51: Set Network

    SECTION 4 Reading from/Writing to ID Tags ■ SET NETWORK This command sets the IP address and subnet mask in ROM. Command Command code First octet Second octet Third octet Fourth octet Parameter Description Parameter Description Type IP address setting: 00 Subnet mask setting: 01 First to fourth octets The address is set in decimal in four octets of three characters each.
  • Page 52 SECTION 4 Reading from/Writing to ID Tags MEMO CIDRW System User’s Manual...
  • Page 53 SECTION 5 Browser Interface Browser Operation Windows Window Configuration CIDRW System User’s Manual...
  • Page 54 SECTION 5 Browser Interface Browser Operation Windows To operate an Amplifier Unit from a browser, connect the Ethernet cables, start a browser on the computer, and specify the IP address of the Amplifier Unit as the URL. The Browser Window will be displayed. The Status Window will be displayed first.
  • Page 55 SECTION 5 Browser Interface Window Configuration IP address of Amplifier Unit Language Buttons Menu Buttons Main Display CIDRW System User’s Manual...
  • Page 56 SECTION 5 Browser Interface Password Entry Window If a Web password is set in the Amplifier Unit, the Password Entry Window will be displayed before the Browser Window is displayed. Enter the password and click the OK Button in this window. If the pass- word is correct, the Status Window will be displayed.
  • Page 57 SECTION 5 Browser Interface If the password is not correct, the following window will be displayed. Click the Retry Button. The Password Entry Window will be displayed again. CIDRW System User’s Manual...
  • Page 58 SECTION 5 Browser Interface Status Window The Status Window displays the model number, firmware version, MAC address, and other information on the Amplifier Unit so that you can check it. Click the Refresh Button at the top of the window to update the displayed information (latest communication, communication history, and H/W status).
  • Page 59 SECTION 5 Browser Interface A Amplifier Unit Information Item Description Comments Model The product model number is displayed. Firmware Version The firmware version is displayed. MAC Address The MAC address is displayed. DIP-SW "Enabled" is displayed if the Amplifier Unit is set to use the IP address that is set on the DIP switch.
  • Page 60 SECTION 5 Browser Interface Setting Window The network settings (IP address and subnet mask) of the Amplifier Unit and the Web password can be set in the Setting Window. The values that are set are enabled when the Amplifier Unit is restarted. If the Save Button is clicked when the password box is empty, the Web password will be cleared.
  • Page 61 SECTION 5 Browser Interface Command Window The Command Window can be used to communicate with ID Tags. The Command Window has two tab pages: "CID R/W" and "V640 Command." V640 Command CID R/W CIDRW System User’s Manual...
  • Page 62 SECTION 5 Browser Interface CID R/W Tab Page The CID R/W Tab Page allows you to read or write ID Tag data by specifying the offset, length, and maximum bytes of CID. If writing is executed, you must also specify the write data. CID Read Button CID Write Button Select this check box to...
  • Page 63 SECTION 5 Browser Interface Item Description Comments Offset Specify the CID offset between 0 and 15 bytes. Length Specify the CID length between 1 and 16 bytes. Maximum byte of CID Specify the maximum CID length between 1 and 16 bytes. Write Data For the write data, specify only the number of bytes for the specified Specify only visible ASCII...
  • Page 64 SECTION 5 Browser Interface V640 Command Tab Page The V640 Command Tab Page allows you to read and write data according to the command format of the Amplifier Unit OK/NG Display Area Page/Write Designation Area Page Designation Area Send Button Write Data Designation Area Select this check box to repeat the command.
  • Page 65 SECTION 5 Browser Interface ■ Page/Write Designation Area Select Read or Write in the Page/Write Designation Area. ■ OK/NG Display Area The command execution results will be displayed as "OK" or "NG" in the OK/NG Display Area. If "NG" is displayed, information on the error will be displayed. •...
  • Page 66 SECTION 5 Browser Interface ■ Page Designation Area Select the check boxes to specify the pages to be read or written. ■ Write Data Designation Area When writing data, specify the data to write to the ID Tag as a hexadecimal string. Specify 16 charac- ters for each page that you specify in the Page Designation Area.
  • Page 67 SECTION 5 Browser Interface Noise Measurement Window The Noise Measurement Window allows you to continuously send the NOISE MEASUREMENT com- mand to the Amplifier Unit and display the results in realtime. The horizontal axis gives the time and the vertical axis gives the noise level (0 to 99). Start/Stop Button Peak noise level Graph Clear Button...
  • Page 68 SECTION 5 Browser Interface MEMO CIDRW System User’s Manual...
  • Page 69 SECTION 6 Troubleshooting Troubleshooting CIDRW System User’s Manual...
  • Page 70: Troubleshooting

    SECTION 6 Troubleshooting Troubleshooting Errors are indicated by the presence or absence of a response to an Amplifier Unit command, and by the indicators. List of Error Messages Response Type Name Description code Host communi- Format error There is a mistake in the command format. (For example, the com- cations error mand portion is undefined, or the page or address specification is inappropriate.)
  • Page 71 SECTION 6 Troubleshooting Operation Check Flowchart ■ From Installation to Trial Operation Errors are indicated by whether or not a response to the test command is received and by the status of the Amplifier Unit indicators. Error occurrence An error has occurred at the Amplifier Unit. RUN indicator Amplifier Unit error Refer to page 70.
  • Page 72 SECTION 6 Troubleshooting • Amplifier Unit Error Check the status of the indicators after transmission of the test command. After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and check again. COMM NORM ERROR Main check points —...
  • Page 73 SECTION 6 Troubleshooting ■ From Trial Operation to Communications Errors are indicated by the status of the indicators after transmission of the write command, and by the response code of the response. Error occurrence Write command sent An error has occurred at the Amplifier Unit. RUN indicator Amplifier Unit error Refer to page 72.
  • Page 74 SECTION 6 Troubleshooting • Amplifier Unit Error Check the status of the indicators after transmission of the command. After taking appropriate correc- tive action, send the write command again and check again. COMM NORM ERROR Main check points — • Influence of background noise (Change installation position) •...
  • Page 75 SECTION 6 Troubleshooting • If the Response Code is 7 : There is a communications error in communications between the CIDRW Head and ID Tag. Check the status of the indicators and the response code of the response after transmission of the command.
  • Page 76 SECTION 6 Troubleshooting MEMO CIDRW System User’s Manual...
  • Page 77: Section 7 Appendix

    SECTION 7 Appendix Specifications and Dimensions Connection Examples Characteristic Data According to Conditions of Use ID Tag Memory Maps Regular Inspection ASCII Code Table Protective Construction CIDRW System User’s Manual...
  • Page 78: Specifications And Dimensions

    SECTION 7 Appendix Specifications and Dimensions Amplifier Units V640-HAM11-ETN-V2 and V640-HAM11-L-ETN-V2 (Unit: mm) DC power supply connector Four operation indicators (15.8) (18.2) 55.5 RS-485 connector (31.95) RS-232C connector DIP switch Four, 4.5-dia. holes (11.5) Mounting dimensions 175±0.5 4-M4 Specifications Item V640-HAM11-ETN-V2 V640-HAM11-L-ETN-V2 Power supply voltage...
  • Page 79 SECTION 7 Appendix ■ Host Communications Specifications Item Description Compliant standards 10Base-T and 100Base-TX Protocol TCP/IP • If the IP address is set on the DIP switch, it will be in the form 192.168.1.@@@. The subnet mask IP Address is always 255.255.255.0 •...
  • Page 80 SECTION 7 Appendix CIDRW Heads V640-HS61 (Unit: mm) Four, 3.5-dia. holes Antenna center Connector Coaxial cable 3.0 dia., standard length 2 m 29.2 Mounting dimensions Antenna center Four M3 or 3.5-dia. holes 21±0.2 Item Specifications Transmission frequency 134 kHz Ambient temperature Operating: 0 to +40°C Storage: -15 to +65°C (with no icing) Ambient humidity...
  • Page 81 SECTION 7 Appendix V640-HS62 (Unit: mm) Four 3.5-dia. (mounting holes) Connector Coaxial cable, Dia.: 3.0, Length: 1.9 m Center of coil 39.2 Ferrite core Mounting Hole Dimensions Center of coil Four M3 or 3.5-dia. holes ± Item Specifications Transmission frequency 134 kHz Ambient temperature Operating: 0 to +40°C...
  • Page 82: Connection Examples

    SECTION 7 Appendix Connection Examples V640-HAM11-ETN-V2 Connect the host device and Amplifier Unit using a LAN cable. Ethernet hub Host device Recommended: W4S1-05B(OMRON) CIDRW Head Amplifier Unit V640-HS61 V640-HAM11-ETN-V2 LAN cable LAN cable Host computer, device controller, etc. CIDRW Head...
  • Page 83: Characteristic Data According To Conditions Of Use

    SECTION 7 Appendix Characteristic Data According to Conditions of Use Maps of Communications Areas (Reference Only) The figures given below for communications areas (communications distances) are reference values only. The maps of communications areas will vary according to the ID Tags that you use, the back- ground metals, the ambient noise, the effects of temperature and so on, and should be thoroughly con- firmed on installation.
  • Page 84 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 85 SECTION 7 Appendix • Parallel Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 86 SECTION 7 Appendix • Parallel Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 87 SECTION 7 Appendix • Vertical Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 88 SECTION 7 Appendix • Vertical Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 89 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 90 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 91 SECTION 7 Appendix • Parallel Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 92 SECTION 7 Appendix • Parallel Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 93 SECTION 7 Appendix • Vertical Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 94 SECTION 7 Appendix • Vertical Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 95 SECTION 7 Appendix ■ V640-HAM11-L-ETN-V2 • Coaxial Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 96 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 97 SECTION 7 Appendix • Parallel Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 98 SECTION 7 Appendix • Parallel Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 99 SECTION 7 Appendix • Vertical Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 100 SECTION 7 Appendix • Vertical Mounting (RI-TRP-DR2B-30) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 101 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 102 SECTION 7 Appendix • Coaxial Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 103 SECTION 7 Appendix • Parallel Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 104 SECTION 7 Appendix • Parallel Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 105 SECTION 7 Appendix • Vertical Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in X direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in X direction (mm) CIDRW System User’s Manual...
  • Page 106 SECTION 7 Appendix • Vertical Mounting (RI-TRP-WR2B) • READ Communications Area (READ) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) • WRITE Communications Area (WRITE) Measurement point -250 -200 -150 -100 Distance in Z direction (mm) CIDRW System User’s Manual...
  • Page 107 SECTION 7 Appendix Mutual Interference Distances (Reference Only) If Amplifier Units are connected using multidrop connections and multiple CIDRW Heads are used, the CIDRW Heads will not process commands simultaneously. In this case, install the CIDRW Heads at least 0.1 m apart from each other. Distance between Antennas and Changes in Communications Distances (Reference Only) •...
  • Page 108 SECTION 7 Appendix Influence of Background Metals (Reference Only) The CIDRW Head can also communicate from an opening in a ceiling panel (metal body). Metal body (material: AL, SUS) (Thickness: 1 mm) However, ensure the distances indicated below between the CIDRW Head and the metal body. If you do not ensure these distances the communications distance will be substantially shortened.
  • Page 109 SECTION 7 Appendix Communications Time Regardless of whether SECS is used or not, take the time required for processing between the host device and Amplifier Units into account when designing the system. Host Response Command Amplifier Unit Communications time Time Description Communications time This is the time required for communications between an ID Tag and the CIDRW Head.
  • Page 110 SECTION 7 Appendix The graph for communications time for communications between the ID Tag and CIDRW Head, and TAT (when the baud rate is 9600 bps), is shown below. The communications time and TAT, however, may increase substantially according to the conditions of use.
  • Page 111 SECTION 7 Appendix BYTE WRITE 8500 8000 7500 7000 Communications time 6500 6000 5500 5000 4500 4000 3500 3000 2500 2000 1500 1000 Number of bytes processed Please confirm beforehand, there is a difference in comparision with V640-HAM11-ETN and V640- HAM11-L-ETN in communication time.
  • Page 112 SECTION 7 Appendix Communications Distance Characteristics vs. Ambient Noise The graph below compares the results of measurement using the noise measurement function with communications distances. At installation implement measures in regard to metal in the vicinity of the CIDRW Head, power supply noise, and atmospheric noise, to ensure that the noise level does not exceed 10.
  • Page 113: Id Tag Memory Maps

    SECTION 7 Appendix ID Tag Memory Maps The memory maps of the RI-TRP-DR2B(-30) and RI-TRP-WR2B(-30) ID Tags are given below. ■ RI-TRP-DR2B(-30) Example of data ID Tag Memory Map segment settings Page 8 bytes/1 page DATASEG LENGTH Carrier ID Carrier (16 byte) "S01"...
  • Page 114: Regular Inspection

    SECTION 7 Appendix Regular Inspection In order to maintain optimum performance of the functions of the CIDRW system, daily and periodic inspections are necessary. Inspection item Detail Criteria Tools required Supply voltage fluctuation Check that the supply voltage fluctuation To be within supply voltage rating. Multimeter at the power supply terminal block is within the permissible range.
  • Page 115: Ascii Code Table

    SECTION 7 Appendix ASCII Code Table Leftmost bits b8 to b5 0000 1001 0010 0011 0100 0101 0110 0111 1000 1101 1010 1011 1100 1101 1110 1111 Right- most bits b4 to b1 Line 0000 TC7(DLE) (SP) 0001 TC1(SOH) DC 0010 TC2(STX) "...
  • Page 116: Protective Construction

    SECTION 7 Appendix Protective Construction is governed by the test methods described below. Check in advance the seal characteristics under the actual environment and conditions of use. IP is the abbreviation of International Protection. ■ IEC (International Electrotechnical Commission) Standard (IEC60529: 2001) (A) First numeral in code: Class of protection against entry of solid foreign material Class Degree of protection...
  • Page 117 Oil-proof Protects against penetration of oil drops or oil spray approaching from any direction. Note. Oil resistance has been tested using a specific oil as defined in the OMRON test method. (JIS C 0920:2003, Appendix 1) CIDRW System User’s Manual...
  • Page 118: Section 8 Revision History

    Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Man. No. Z361-E1-03 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.
  • Page 120 The Netherlands Hoffman Estates, IL 60169 U.S.A Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 © OMRON Corporation 2015-2017 All Rights Reserved. OMRON (CHINA) CO., LTD. OMRON ASIA PACIFIC PTE. LTD. In the interest of product improvement, No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, specifications are subject to change without notice.

This manual is also suitable for:

V640-ham11-etn-v2V640-ham11-l-etn-v2V640-hs61V640-hs62

Table of Contents