C.10 MEMOBUS/Modbus Data Table
Table below lists all MEMOBUS/Modbus data. There are three types of data: command data, monitor data, and broadcast
data.
u

Command Data

It is possible to both read and write command data.
Note: Bits that are not used should be set to 0. Refrain from writing to reserved registers.
Register No.
0000H
Reserved
Operation Signals and Multi-function Inputs
bit 0
bit 1
bit 2
bit 3
bit 4
0001H
bit 5
bit 6
bit 7
bit 8
bit 9
bit A
bit B to F
0002H
Frequency Reference Units are determined by parameter o1-03.
0003H-0005H
Reserved
0006H
PID Target, 0.01% units, signed
0007H
Analog Output Terminal AM Setting (10 V / 4000 H)
0008H
Reserved
Settings for Multi-Function Digital Outputs
bit 0
0009H
bit 1
bit 2
bit 3 to F
000AH
Pulse Output Terminal MP Setting, 1 Hz units, Setting Range: 0 to 32000
000BH-000EH
Reserved
Control Selection Setting
bit 0
bit 1
bit 2 to B
000FH
bit C
bit D
bit E
bit F
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
H5-12 = 0: Forward Run Command (0 = Stop, 1 = Forward Run)
H5-12 = 1: Run Command (0 = Stop, 1 = Run)
H5-12 = 0: Reverse Run Command (0 = Stop, 1 = Reverse Run)
H5-12 = 1: Forward/Reverse (0 = Forward, 1 = Reverse)
External Fault (EF0)
Fault Reset
Multi-Function Input 1
Function is ComRef when H1-01 = 40 (Forward/Stop).
ComRef explanations.
Multi-Function Input 2
Function is ComCtrl when H1-02 = 41 (Reverse/Stop).
ComCtrl explanations.
Multi-Function Input 3
Multi-Function Input 4
Multi-Function Input 5
Multi-Function Input 6
Reserved
Reserved
Contact Output (terminal MA/MB-MC)
Photocoupler Output 1 (terminal P1-PC)
Photocoupler Output 2 (terminal P2-PC)
Reserved
Reserved
PID Target Input
Reserved
Enable Terminal S5 Input for Broadcast Data
Enable Terminal S6 Input for Broadcast Data
Reserved
Reserved
C.10 MEMOBUS/Modbus Data Table
Contents
Refer to d: Reference Settings on page 134
Refer to d: Reference Settings on page 134
for
for
C
367

Hide quick links: