B.2 Parameter Table
No.
Name
U4-14
Peak Hold Output Frequency
Motor Overload Estimate
U4-16
(oL1)
Frequency Reference Source
U4-18
Selection
Frequency Reference from
U4-19
MEMOBUS/Modbus
Comm.
U4-20
Option Frequency Reference
Run Command Source
U4-21
Selection
MEMOBUS/Modbus
U4-22
Communications Reference
U4-23
Option Card Reference
U5-01
PID Feedback
U5-02
PID Input
U5-03
PID Output
U5-04
PID Setpoint
U5-05 PID Differential Feedback
U5-06 PID Adjusted Feedback
336
Description
Displays the output frequency when operating at the peak
hold current.
100% = oL1 detection level
Displays the source for the frequency reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
2 = Reference 2 (b1-15)
Y-nn: indicates the reference source
0-01 = Operator (d1-01)
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
2-02 to 17 = Multi-step speed (d1-02 to 17)
3-01 = MEMOBUS/Modbus comm.
4-01 = Option
5-01 = Pulse Input
6-01 = CASE
7-01 = FDBs
Displays the frequency reference provided by MEMOBUS/
Modbus (decimal).
Displays the frequency reference input by an option card
(decimal).
Displays the source for the Run command as XY-nn.
X: Indicates which Run source is used:
1 = Reference 1 (b1-02)
2 = Reference 2 (b1-16)
Y: Input power supply data
0 = Operator
1 = External terminals
2 = Not used
3 = MEMOBUS/Modbus communications
4 = Option
5 = Not used
6 = CASE
7 = FDBs
nn: Run command limit status data
00: No limit status.
01: Run command was left on when stopped in the PRG
mode.
02: Run command was left on when switching from
LOCAL to REMOTE operation.
03: Waiting for the soft charge bypass contactor after the
power is switched on (Uv or Uv1 flashes after 10 seconds).
04: Waiting for "Run Command Prohibited" time period to
end.
05: Fast-stop (digital input (H1- = 15), operator)
06: b1-17 (run command given at power-up).
07: During Baseblock while coast to stop with timer
08: Frequency reference is below minimal reference during
Baseblock
09: Waiting for Enter command
Displays the drive control data set by MEMOBUS/Modbus
communications register No. 0001H as a 4 digit
hexadecimal number.
Displays drive control data set by an option card as a 4 digit
hexadecimal number.
U5: PID Monitor
Use U5 parameters to view application-specific settings.
Displays the PID feedback value in.
Displays the amount of PID input (deviation between PID
target and feedback).
Displays PID control output.
Displays the PID setpoint.
Displays the 2nd PID feedback value if differential
feedback is used.
Displays the subtraction value of both feedback values if
differential feedback is used.
Control
Analog Output
Unit
Level
V/f
10 V: Max
0.01H
A A A
frequency
z
100% = oL1
0.1% A A A
detection level
A A A
A A A
A A A
A A A
A A A
A A A
0.01
A A A
%
0.01
A A A
%
0.01
A A A
%
10 V: 100% (max.
freq.)
0.01
A A A
%
0.01
A A A
%
0.01
A A A
%
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
Mode
Addr.
Hex
O
P
LV
M
7D0
7D8
7DA
7DB
7DD
7DD
7DE
7DF
57
63
64
65
7D2
7D3