Omron V1000 User Manual page 318

Compact vector control drive 200 v class three-phase input 0.1 to 15 kw, 200 v class single-phase input 0.1 to 4.0 kw, 400 v class three-phase input 0.2 to 15 kw
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

H1-
Function
Setting
7D
Short-Circuit Braking (N.C.)
7E
Forward/Reverse Detection
7F
Bi-directional PID output selection
90 to 96 FBDs Digital Inputs 1 to 7
9F
FBDs enable
No.
Name
Terminal MA, MB and MC Function
H2-01
Selection (relay)
Terminal P1 Function Selection (open-
H2-02
collector)
Terminal P2 Function Selection (open-
H2-03
collector)
H2-06
Watt Hour Output Unit Selection
<40> The availability of certain functions depends on the control method used.
H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency reference selection
A
Run command selection
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Not used/Through Mode
10
Minor Fault
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
H1 Multi-Function Digital Input Selections
Open: Short-Circuit Braking
Closed: Normal operation
Direction of rotation detection (for V/f with Simple PG Feedback)
Enables or disables conversion of PID output to bi-directional reference
if parameter d4-11 = 1.
Open: Bi-directional output disabled
Closed: Bi-directional output enabled
Reserved for FBDs input functions
Open: FBDs enabled
Closed: FBDs disabled
H2: Multi-Function Digital Outputs
Use H2 parameters to assign functions to the multi-function digital outputs.
Refer to H2 Multi-Function Digital Output
Settings on page
setting values.
Determines the unit for the watt hour output
signal (H2- = 39). If a digital output is set
to this function, a 200 ms pulse signal is output
when the what hour counter increases
according to the unit selected. Intended to drive
a counter, meter or PLC for logging kWh.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
H2 Multi-Function Digital Output Settings
Closed: A Run command is active or voltage is output.
Closed: Output frequency is 0.
Closed: Output frequency equals the speed reference (plus or minus the hysteresis set
to L4-02).
Closed: Output frequency and speed reference equal the value in L4-01 (plus or minus
the hysteresis of L4-02).
Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis
determined by L4-02.
Closed: Output frequency is greater than or equal to the value in L4-01, with hysteresis
determined by L4-02.
Closed: Drive Ready. The drive is powered up, not in a fault state, and in the Drive
mode.
Closed: DC bus voltage is below the Uv trip level set in L2-05.
Closed: There is no output voltage
Open: External Reference 1 or 2 supplies the frequency reference
Closed: Digital operator supplies the frequency reference.
Open: External Reference 1 or 2 supplies the Run command
Closed: Digital operator supplies the Run command.
Closed: Output current/torque exceeds the torque value set in parameter L6-02 for
longer than the time set in parameter L6-03.
Closed: Loss of the analog frequency reference detected. Enabled when L4-05 = 1.
Closed: Braking resistor or transistor is overheated or faulted out. This selection
requires that braking resistor protection parameter be set for ERF (L8-01 = "1").
Closed: Fault occurred (other than CPF00 and CPF01).
Set this value when the terminal is not used, or when using the terminal in the pass-
through mode.
Closed: An alarm is triggered.
Description
Description
Range
0 to 192
317
for a description of
Description
B.2 Parameter Table
Control
Mode
OL
V/f
V
-
-
O
-
O
O
O
O
O
O
Control
Mode
Addr.
Def.
Hex
O
P
V/f
LV
M
E
A A A
40B
0
A A A
40C
<40>
2
A A A
40D
0 to 4
0
A A A
437
Control
Mode
V/f O
LV
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
O O O
Pg.
PM
O
169
-
169
O
169
O
169
O
169
Pg.
169
169
169
177
Pg.
P
M
170
170
170
171
171
172
172
172
172
173
173
173
173
173
B
173
173
173
317