Paradyne 9161 Reference Manual page 85

Zhone 9161 mux: reference guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

Setting Up
4-42
Procedure
1. Follow this menu selection sequence:
Configuration Edit/Display
Assignment
2. The Sync Data Port Assignments screen appears. Enter one of the following
into the Assign To field:
If you want to assign to . . .
Network interface timeslots
DSX-1 interface timeslots on the 9161
Single T1 NAM
Another Sync Data port
3. Enter the number of DS0s to allocate.
4. Enter one of the following into the Assign By field:
Enter . . .
To . . .
Channel
Assign ports individually. However, a Sync Data port can be
assigned to multiple timeslots which do not have to be
contiguous. As you assign multiple timeslots to a port, the data
port rate increases by the Port Base Rate defined on the
Synchronous Data Port Options screen (see
Data Ports on page
Block
Assign a block of contiguous channels by specifying the number
of DS0s. The number of DS0s is limited to the largest
contiguous block of timeslots, and only starting timeslots that
have enough contiguous timeslots following will be selectable.
ACAMI
Assign a block of contiguous channels as in the Block method,
except that the number of channels assigned is twice the
number of DS0s to allocate. Every other timeslot is filled with all
ones to maintain ones density on the interface.
5. Move the cursor to the next editable timeslot (underlined). Use the spacebar
or type in the desired slot and port. Repeat this step until all desired timeslots
are assigned.
6. Select Save to save the assignments, or press ESC to save and return to the
Cross Connect menu.
September 1997
Cross Connect
Sync Data Port
Then enter . . .
Net1 or Net2
DSX01-1
Port
4-16).
Configuring Sync
9161-A2-GH30-20

Advertisement

Table of Contents
loading

This manual is also suitable for:

9261

Table of Contents