9161-A2-GH30-20
Object
Description
dsx1TransmitClock
Supported as read-only.
Source
Specifies the timing source
(dsx1ConfigEntry 12)
for the transmit clock.
dsx1Fdl
Specifies how the facility
(dsx1ConfigEntry 13)
data link is being used.
More than one value may
be active at the same time.
September 1997
MIB Descriptions
Setting/Contents
Supports only the following
values:
loopTiming(1) – Use the
recovered receive clock as the
transmit clock.
localTiming(2) – Use the
unit's internal clock as the
transmit clock.
ThroughTiming(3) – Use the
recovered receive clock from
another interface (e.g., T1,
Port, or External), as the
transmit clock.
If the value is not dsx1fdl-none,
then dsx1Att54016 must be set.
Supports the following values:
dsx1other(1) – Send SNMP
data over the FDL.
dsx1Ansi-T1403(2) – Support
ANSI PRMs on the network
T1 interface as specified by
ANSI T1.403.
dsx1Att-54016(4) – The FDL
supports the requirements
specified by AT&T publication
TR54016.
dsx1Fdl-none(8) – The unit
does not use the FDL. Applies
to the DSX-1 T1 interface.