Mixed Operation Of Sinamics S120 And S220 Components - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

System overview
3.1 Overview of the booksize system
The components are arranged in the following groups:
Designation
Line-side power components
Line Modules
DC link components
Motor Modules
Motor-side power components
Control Units
Additional system components
3.1.2

Mixed operation of SINAMICS S120 and S220 components

Overview
Mixed operation of SINAMICS S120 booksize and S220 booksize components is possible.
Requirement
Danger to life due to unsuitable firmware version
Operating SINAMICS S220 booksize components with an unsuitable firmware version can
result in unsafe operating states. For example, it can lead to converter components
overheating, a motor unexpectedly accelerating or safety functions not functioning.
• When using a SINAMICS S220 Smart Line Module, use a Control Unit with firmware V5.2 SP3
• When using a SINAMICS S220 Motor Module, use a Control Unit with firmware V5.2 SP3 HF9
Description
The article numbers of SINAMICS S220 booksize components start with 6SL5.
32
Function, use
Switching the energy supply and to comply with EMC
regulations
Central energy supply into the DC link
Additional components for the DC link
Inverters, which draw energy from the DC link and
supply the connected motors
Additional components on the output side
Processing cross-axis drive and technological func‐
tions
Extend the functionality, provide various interfaces to
encoders and process signals
WARNING
HF10 or later.
or later.
Components (examples)
Fuses
Contactors
Reactors
Filters
Smart Line Modules
Braking Modules
Capacitor Module
Control Supply Modules
Motor Modules
Motor reactors
Control Unit
Option Board
Communication Board
Terminal Modules
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA

Advertisement

Table of Contents
loading

Table of Contents