Led Description - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

Motor Modules
8.3 Motor Modules 3 ... 30 A and 2x3 ... 2x18 A
8.3.2

LED description

Response of the LEDs in operation
Table 8-5
Meaning of the LEDs on the Motor Module
LEDs
RDY 1
RDY 2
for axis 1
for axis 2
1)
Green
Green
Orange
Orange
Red
Red
Red/Green
Red/Green
(0.5 Hz)
(0.5 Hz)
158
DC LINK
 
The electronics power supply is missing or outside
the permissible tolerance range.
The component is ready for operation. Cyclic DRIVE-
2)
CLiQ communication is taking place.
The DC link voltage is < 50 V.
The DC link voltage is present.
Orange
The DC link voltage lies above the permissible toler‐
ance range.
Red
DRIVE-CLiQ communication is being established.
Orange
2)
This component has at least one fault.
Remark:
The LED is controlled irrespective of the correspond‐
ing messages being reconfigured.
2)
Firmware is being downloaded.
Description, cause
Equipment Manual, 09/2023, A5E53307519B AA
Remedy
 
Check the 24 V supply.
Check the line voltage.
Resolve and acknowl‐
edge the fault.