Connecting The Motor; Connectable Cable Cross-Sections; Selecting Cable Lugs - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

8.5.12

Connecting the motor

8.5.12.1

Connectable cable cross-sections

Description
Table 8-40
Output current [A]
85 A ... 200 A
To ensure touch protection IPxxB according to IEC 60529, reduction collars must be used for cable cross-
1)
sections of 16 mm² - 95 mm² (AWG 6 - AWG 3/0).
8.5.12.2

Selecting cable lugs

Description
Here you can see the dimensions of the motor connection block for selecting the motor
connection cable and the ring or tubular cable lug.
Figure 8-81
Table 8-41
Dimensions of the motor connection block in mm (inch)
 
Maximum dimensions
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
Conductor cross-sections of the motor cable for Motor Modules 85 A, 132 A and 200 A
Dimensions of the motor connection block for Motor Modules 85 A, 132 A and 200 A
a
b
59.8 (2.35)
28.1 (1.1)
8.5 Motor Modules 85 A, 132 A and 200 A
Cable cross-sections
Single core connection:
16 ... 150 mm
 (AWG 6 ... 300 kcmil)
2
Two-wire connection:
16 ... 50 mm
 (AWG 6 ... 1/0)
2
c
d
21.2 (0.83)
29.4 (1.16)
Motor Modules
1)
e
f
25.4 (1.0)
22.5 (0.88)