Motor Modules
8.5 Motor Modules 85 A, 132 A and 200 A
8.5.2

LED description

Response of the LEDs in operation
Table 8-33
Meaning of the LEDs on the Motor Module
LEDs
RDY 1
DC LINK
for axis 1
1)
Green
Orange
Red
Orange
Orange
1)
Red
1)
Red/Green
(0.5 Hz)
216
Description, cause
 
The electronics power supply is missing or outside the permis‐
sible tolerance range.
The component is ready for operation. Cyclic DRIVE-CLiQ com‐
munication is taking place.
The DC link voltage is < 50 V.
The DC link voltage is present.
The DC link voltage lies above the permissible tolerance range. Check the line voltage.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Remark:
The LED is controlled irrespective of the corresponding mes‐
sages being reconfigured.
Firmware is being downloaded.
Remedy
 
Check the 24 V supply.
Resolve and acknowledge
the fault.