Motor Modules
8.5 Motor Modules 85 A, 132 A and 200 A
Note
Use of protective gloves
We recommend that you wear protective gloves when installing Motor Modules 85 A, 132 A and
200 A.
The following requirements for installation must be satisfied:
• Control cabinet panel/mounting panel:
– Housing: Sheet steel
– Panel thickness: 3 mm (0.12 in)
– Tensile strength: ≥ 270 N/mm
• 4 x M6 screws
• 4 x M6 washers
Procedure
Table 8-38
Rated current
Width
Rear view
Proceed as follows to mount the Motor Modules onto the mounting panel:
1. Prepare the mounting panel.
2. First, screw the 4 screws in far enough so that you can attach the component.
3. Attach the component.
4. Tighten the screws finger-tight. Tightening torque: 0.5 Nm (4.4 lbf in)
5. Then tighten the screws fully. Tightening torque: 6 Nm (53.1 lbf in)
230
Rear views of Motor Modules 85 A, 132 A and  200 A in mm and (inch)
85 A and 132 A
150 mm
acc. to DX51 EN 10346
2
200 A
200 mm
Equipment Manual, 09/2023, A5E53307519B AA