SIMATIC
S7-400
Counter module FM 450-1
Equipment Manual
03/2022
A5E03648739-AC
Preface
Product Overview
This is how the FM 450-1
counts
Installation and Removal
Wiring
Parameter assignment
Program
Commissioning
Modes, settings,
parameters and commands
Encoder signals and their
evaluation
Assignment of the DB
Errors and diagnostics
Technical Data
Spare parts
References
1
2
3
4
5
6
7
8
9
10
11
12
13
14

Advertisement

Table of Contents
loading

Summary of Contents for Siemens FM 450-1

  • Page 1 Preface Product Overview This is how the FM 450-1 counts SIMATIC Installation and Removal S7-400 Counter module FM 450-1 Wiring Parameter assignment Equipment Manual Program Commissioning Modes, settings, parameters and commands Encoder signals and their evaluation Assignment of the DB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Scope of this manual The present manual contains the description of the FM 450-1 valid at the time the manual is published. We reserve the right to describe changes to the functions of the FM 450-1 in the form of product information.
  • Page 4 Technical Support You can access technical support for all A&D projects via the following: • Online support request form: (http://www.siemens.com/automation/support-request) Service & Support on the Internet In addition to our documentation, we offer a comprehensive online knowledge base on the...
  • Page 5: Table Of Contents

    Product Overview ..........................9 Chapter overview......................... 9 Properties ..........................9 Fields of applications of the FM 450-1 ................11 The FM 450-1 hardware ..................... 13 The FM 450-1 software ...................... 15 This is how the FM 450-1 counts ......................17 Basics ..........................
  • Page 6 General technical specifications..................99 12.2 Technical Data ........................99 12.3 Standards and approvals ....................101 12.3.1 Currently valid markings and approvals ................101 12.3.2 CE approval ........................102 12.3.3 CCC approval ........................103 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 7 105 12.3.9 Approval for Australia and New Zealand ................106 12.3.10 Approval for the Korea and South Korea ................106 Spare parts............................107 References ............................109 Glossary ............................. 111 Index ..............................115 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 8 Table of contents Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 9: Product Overview

    Properties Properties The FM 450-1 is a fast counter module to be used in the S7-400 automation system. There are two counters on the module which can work in the following counting ranges as required: • 0 to 4 294 967 295 (0 to 2 - 1) •...
  • Page 10 1.2 Properties Load value You can determine an initial value (load value) for each counter on the FM 450-1 The counter is set at the initial value if a software or hardware-related signal to the module comes up. Hardware interrupts When comparison values are reached, for overflow, underflow and/or for zero crossing of a counter, the FM 450-1 can trigger a Hardware interrupt.
  • Page 11: Fields Of Applications Of The Fm 450-1

    B switched on. If the programmed number of parts are in the box, the FM 450-1 stops the motor for belt B and switches on the motor for belt A so that the box can be transported away.
  • Page 12 Product Overview 1.3 Fields of applications of the FM 450-1 FM 450-1 Belt A Motor Light barrier Motor Gate Belt B Figure 1-1 Example application for an FM450-400 in the S7-400 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 13: The Fm 450-1 Hardware

    Order number and version The full order number of the FM 450-1 is shown on the rating plate. The abbreviated order number and the version of the FM 450-1 are marked on the top end of the front of the module.
  • Page 14 Front connector coding If you hook in the front connector, the front connector coding engages. Thereafter this front connector can only be attached to an FM 450-1 module. Labeling strips A plate block with four labeling strips is included with the module. These strips can be labeled individually with the corresponding signal names.
  • Page 15: The Fm 450-1 Software

    The software for the CPU consists of the FC CNT_CTRL function, which is invoked in the CPU user program. This FC enables communication between the CPU and the FM 450-1. In addition, there is also the FC DIAG_INF for the FM 450-1 with which you can transmit diagnostic data into the DB of FC CNT_CTRL.
  • Page 16 Product Overview 1.5 The FM 450-1 software Figure 1-3 Layout of a SIMATIC S7-400 with an FM 450-1 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 17: This Is How The Fm 450-1 Counts

    Load value You can lay down an initial value for each of the two FM 450-1 counters from which the counting is to begin. This initial value is the load value. You can specify any value within the count limits for the load value.
  • Page 18 This is how the FM 450-1 counts 2.1 Basics Continuous counting If when counting in the up direction a counter has reached the high count limit and a further count pulse comes, then the counter jumps to the low count limit and begins to total the count pulses;...
  • Page 19: Gate Functions

    Many applications require that the counting process should be started or stopped at a specifically defined point in time, depending on other events. In the case of the FM 450-1 starting and stopping the counting process like this take place via a gate function. If the gate is opened, count pulses can reach a counter and the counting process is started.
  • Page 20 This is how the FM 450-1 counts 2.2 Gate functions Counter status Count pulses Gate signal Open Close gate gate Figure 2-4 Opening and closing a gate Ending counting process with the gate stop function You can end the counting process when counting with the SW gate and when counting with the HW gate with the respective gate stop function.
  • Page 21: Installation And Removal

    The start address of the FM 450-1 is required for the purpose of communication between the CPU and the FM 450-1. The start address is entered into the DB of the FC CNT_CTRL (refer to chapter "Program (Page 39)" and chapter "Assignment of the DB (Page 87)"). The entry is either made with the program editor or out of the user program.
  • Page 22: Installing The Fm 450-1

    1. Hook the FM 450-1 in at the top and rotate it down. 2. Screw the FM 450-1 tight (torque approx. 0.8 to 1.1 Nm). 3. Label the FM 450-1 with its slot number. For this purpose use the number wheel enclosed with the rack.
  • Page 23 Installation and Removal 3.4 Removal of the FM 450-1 Further information Further information on the installation and removal of modules is to be found in manual /1/. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 24 Installation and Removal 3.4 Removal of the FM 450-1 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 25: Wiring

    Wiring Chapter overview Chapter overview In this chapter you will find information on wiring the FM 450-1 • Terminal assignment of the front connector. • Terminal functions. • Notes on the selection of cables. • Procedure when wiring the front connector.
  • Page 26 Wiring 4.2 Terminal assignment of the front connector Figure 4-1 Front connector of the FM 450-1 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 27 Ground for encoder power supply 5,2 VDC 5,2 V encoder pow‐ er supply 24 VDC 24 V encoder power supply Counter 1 Digital input 1I0 Digital input 1I1 Digital input 1I2 (set counter) Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 28 The module generates a 5.2 VDC voltage from the 1L+/1M auxiliary voltage at a maximum current of 300mA per count channel; this voltage is available on the respective "DC5.2V" terminal to supply a 5 V encoder with short circuit-proof voltage. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 29 Input filter 1 Input filter 2 (default setting) Typical input delay 1 μs 15 μs Maximum count frequency 200 kHz 20 kHz Minimum pulse width of the count signals 2.5 μs 25 μs Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 30 25 μs Digital outputs For the purpose of directly initiating control processes, the FM 450-1 has the digital outputs 1Q0 and 1Q1 (for counter 1) or 2Q0 and 2Q1 (for counter 2) that are supplied via the load voltage 2L+.
  • Page 31: Wiring Front Connectors

    Wiring 4.3 Wiring Front Connectors The 2L+ / 2M load voltage is not monitored by the FM 450-1. Wiring Front Connectors Cables There are a few rules you must observe when selecting the cables: • The cables for the digital inputs must be shielded.
  • Page 32 If you supply the encoder with external voltage, you must also connect the ground of this external voltage supply to the ground of the CPU. The following figure shows details relating to the connection of incremental 24 V encoders. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 33 • A wire end ferrule is not required. If you use wire end ferrules, they must be of the type without insulating collars in compliance with DIN 46228 Form A, short type! Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 34: Module Status After Power Is Switched On

    Proceed as follows when wiring the front connector: WARNING Injury to persons can occur. If you wire the FM 450-1 front connector when the power is switched on, you may injure yourself owing to an electric shock. Always switch off power before you wire the FM 450-1! 1.
  • Page 35 • Gate function switched off (i.e. gate open) • Status messages are updated This setting corresponds to the default setting of the module. RESET status This module status (default setting) is also called RESET status. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 36 Wiring 4.4 Module status after power is switched on Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 37: Parameter Assignment

    In this chapter you will learn how to install and start parameter assignment screen forms. The parameter assignment screen forms have an integrated help function to support you with parameter assignment and commissioning of the FM 450-1. Installing and calling parameter assignment screen forms...
  • Page 38 Calling parameter assignment screen forms The parameter assignment screen forms are displayed automatically after successful installation, if you assign the FM 450-1 parameters within the hardware configuration Calling the integrated help There is an integrated online help for the parameter assignment screen forms that you can call in any phase of parameter assignment either with the F1 key or with the Help button.
  • Page 39: Program

    Chapter overview Chapter overview In this chapter you can find all the information you require to program the FM 450-1 in the S7-400. Two STEP 7 blocks are provided for integrating the FM 450-1 into a user program and make handling the desired functions as easy as possible for you.
  • Page 40 • The following valid data must be assigned to the DB required for the FC CNT_CTRL: – Module address Set the module address (basic address of the FM 450-1) when you configure your hardware. The module address must be entered in the MOD_ADR parameter in the DB.
  • Page 41 "Stop gate" counter control bit sets and resets this queries this OT_ERR_A INPUT BOOL Acknowledge operator error sets and resets this queries this OT_ERR OUTPUT BOOL Operator error occurred queries this sets and resets this Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 42 Processing jobs You initiate a job for the FM 450-1 by means of the L_DIRECT, L_PREPAR, T_CMP_V1, T_CMP_V2, RES_SYNC, RES_ZERO, OT_ERR_A and GATE_STP FC parameters. Depending on the job you must enter the load value or a comparison value into the instance DB prior to the calling the FC.
  • Page 43: The Fc Diag_Inf Function

    The FC DIAG_INF function Functionality The FC DIAG_INF reads data record DS1 from the FM 450-1 and makes it available to you in the DB of the FC CNT_CTRL. Transfer proceeds as follows: • If initiation parameter (IN_DIAG=TRUE) the DS1 is read out from the FM°450-1.
  • Page 44: Example Application

    Example for the use of the FC CNT_CTRL The following example is representative for all functions and demonstrates the "Transfer load value to FM 450-1" and "Start counter" functions to show how the FC°CNT_CTRL can be applied. +1000; // Enter load value into KANAL1.LOAD_VAL;...
  • Page 45 The value to be transferred must have been entered in the DB°1. The load value is transferred and started: When the FC is called, the load value of a channel is transferred to the FM 450-1. Calling the FC °CNT_CTRL selects either the L_DIRECT parameter or the L_PREPAR parameter. The L_DIRECT selection bit specifies that the load value will be loaded directly onto the counter (L_DIRECT=1).
  • Page 46: Technical Specifications Of The Blocks

    634 bytes 326 bytes Assignment in local data area 4 bytes 38 bytes System function called SFC 51 RDSYSST • Internal update time of the FM°450-1: 0.5°ms. • SDB 100: approx. 240°bytes Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 47: Commissioning

    Commissioning Chapter overview Chapter overview In this chapter you will find checklists for commissioning the FM 450-1. These checklists enable you to • check all working steps up to full operation of the module, • avoid operating faults by the module.
  • Page 48 5.2 VDC and /A, B and /B, N and /N 5.2 V encoder power supply Encoder signal A Encoder signal /A Encoder signal B Encoder signal /B Encoder signal N Encoder signal /N Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 49 Direction level B* Counter 2: Terminal Name Function 24-V pulse encoder with di‐ Ground for encoder power rection level supply 24 VDC 24 V encoder power supply Encoder signal A* Direction level B* Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 50 Digital output Q1 Connecting auxiliary volt‐ Terminal Name Function age and load voltage Encoder supply 24V auxiliary voltage Auxiliary voltage ground Supply for digital inputs and 24V load voltage outputs Load voltage ground Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 51: Working Steps For Parameter Assignment

    Use the following checklist to check and document the working steps during parameter assignment of the FM°450-1. Assign the parameters of the FM°450-1 counters in the same order as the check list. Working step Options/procedure Assign the FM 450-1 pa‐ Select encoders for counter 1 rameters 5-V encoder with symmetri‐ Monitoring...
  • Page 52 Commissioning 7.3 Working steps for parameter assignment Step Options/procedure Assign the FM 450-1 pa‐ Select encoders for counter 2 rameters 5-V encoder with symmetri‐ Monitoring A + B + N cal signals A + B None 24-V encoder with asym‐...
  • Page 53 Commissioning 7.3 Working steps for parameter assignment Step Options/procedure Assign the FM 450-1 pa‐ Specify mode for counter 1 rameters Continuous counting Without gate With SW gate With HW gate Single counting With SW gate With HW gate Periodic counting...
  • Page 54 Commissioning 7.3 Working steps for parameter assignment Step Options/procedure Assign the FM 450-1 pa‐ Specify the behavior of the digital outputs for counter 1 rameters Output 1Q0 Disable Active from comparison value 1 to overflow Active from comparison value 1 to underflow Active for "pulse duration"...
  • Page 55 Commissioning 7.3 Working steps for parameter assignment Step Options/procedure Assign the FM 450-1 pa‐ Enable digital outputs rameters CTRL_DQ0 in DB 1 CTRL_DQ1 in DB 1 Specify load value and comparison values for counter 1 and enter in DB Load value...
  • Page 56 Commissioning 7.3 Working steps for parameter assignment Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 57: Modes, Settings, Parameters And Commands

    Starting from the current counter status the FM°450-1 counts continu‐ (with or without gate) ously. Single counting with SW gate When the gate opens, the FM 450-1 counts from the load value to the or with HW gate count limit. Periodic counting with SW...
  • Page 58 Modes, settings, parameters and commands 8.2 Overview of modes, settings and commands Which settings are available? You can adapt the FM 450-1 to your count job by means of the following five settings: Table 8-2 The FM 450-1 settings Name...
  • Page 59: Basics On Calling Modes, Settings And Commands

    Infinite counting Overview In this mode an FM 450-1 counter counts infinitely from the current counter status: • When counting up, if the counter reaches the upper count limit and a further count pulse comes, it jumps to the lower limit and continues counting from there without any pulse loss.
  • Page 60 In addition you can end the count process when counting with the SW gate or HW gate by means of the gate stop function of the relevant counter. For this purpose you set the GATE_STP input parameter of the FC CNT_CTRL. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 61: Single Counting

    Applying positive edge to input 1I1 (2I1) In the case of a level-controlled HW gate, a signal at output 1I0 (2I0) is used to reopen the gate and set the relevant counter to the load value. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 62: Periodic Counting

    GATE_STP input parameter of the FC°CNT_CTRL. Periodic counting Overview In this mode an FM 450-1 counter counts once from the load value up to the count limit, jumps back to the load value and continues to count. Select gate function In this mode you can select the gate function Options: •...
  • Page 63 You open and close the SW gate and set the counter to the load value by setting or resetting the relevant bit in the DB of the FC°CNT_CTRL in the user program (see chapter "Assignment of the DB (Page 87)"). When you open the SW gate, the FM 450-1 starts counting from the load value.
  • Page 64: Count Range

    +32 bits" and "-31 to +31 bits". Count ranges The FM 450-1 counts within different limits in the count ranges 0 to +32 bits and -31 to +31 bits. In each case an overflow or an underflow is identified at the range limits.
  • Page 65: Setting: Behavior Of The Digital Outputs

    You enter the two comparison values in the DB of the FC CNT_CTRL (CMP_V1, CMP_V2) and transfer them to the FM 450-1 by setting the bits T_CMP_V1 or T_CMP_V2 (see the section "Assignment of the DB (Page 87)"). The count is not affected by this.
  • Page 66 The output is activated when the comparison value is reached for the time the pulse lasts, irre‐ rection spective of the counting direction. A shaded in area in the table signifies: The output is active. t = pulse duration Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 67: Setting: Pulse Duration

    The pulse duration is without effect if the output is to be set between the comparison value and overflow or underflow. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 68: Command: Open And Close Gate

    Command: Open and close gate Overview The FM 450-1 counters have the following gates: • A hardware gate (HW gate) which you can open and close level controlled or edge controlled. • A software gate (SW gate) which you can open and close via control bits in the user program.
  • Page 69 IN 0) and CH 1 IN 1 (CH 2 IN 1) and, within the user program, in the STS_STA and STS_STP bit of the DB of the FC°CNT_CTRL. Gate status The gate status is indicated in the STS_GATE bit within the user program. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 70 Opening and closing of a HW or SW gate can be used to trigger a hardware interrupt (see section "Initiating a process interrupt (Page 76)".) Default setting In the default setting all gates are open; the count pulses are counted. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 71: Command: Set Counter

    You use the zero mark of the encoder if you want to synchronize the counter to a specific counter status at a specific point in your process. Hence you achieve greater precision in the count process. The counter is set independent of the mode. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 72 You can specify the behavior of an FM°450-1 counter with a positive edge at input 1I2 (2I2) with the ENSET_UP and ENSET_DN variables in the DB of the FC_CNT_CTRL and by means of parameter assignment. Behavior of the FM 450-1 ENSET_UP set The counter is only set in the case of up counting...
  • Page 73 1I2 result in the setting of the counter. Count pulses Input1I2 ENSET_UP Counter set Counter not set Counter set Counter set Figure 8-8 Multiple setting of counter 1 with input 1I2 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 74 With the ENSET_UP and ENSET_DN variable is the DB of the FC CNT_CTRL and by assigning parameters, you specify the behavior of the respective FM 450-1 counter in the case of a rising edge of the zero mark.
  • Page 75 Counter pulses Zero mark Input 1I2 ENSET_UP Counter set Counter set Counter Counter set Counter Counter set not set not set Figure 8-10 Multiple setting of counter 1 with the zero mark Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 76: Initiating A Process Interrupt

    Initiating a process interrupt Introduction For the individual counters of the FM 450-1 you can set which events are to trigger a hardware interrupt during operation. For this purpose you parameterize the counter interrupts in the parameter assignment screen marks.
  • Page 77 This can result in the diagnostic interrupt "hardware interrupt lost" depending on the parameters assigned. Default setting No hardware interrupt is assigned in the default setting. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 78 Modes, settings, parameters and commands 8.12 Initiating a process interrupt Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 79: Encoder Signals And Their Evaluation

    Differential signals A and /A, B and /B, N and /N 24-V incremental encoder A*, B* and N* 24-V pulse encoder 24-V with directional signal 24-V proximity switch 24 V without directional signal Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 80: 5-V Differential Signals

    (monitoring.) An error state at all three signals indicates a defective encoder, or a short-circuit at the "5.2 V DC" encoder supply, or a missing encoder. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 81: 24-V Signals

    24-V pulse encoders without/with direction signal Encoders such as proximity switches (BERO) or light barriers return only a count signal which you wire to terminal A* of the front connector. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 82 You can not reverse the direction of these count signal by inverting the B* signal. Note This type of evaluation may cause the count value to "drift off" at the edges if count signal oscillates, as all signals are added. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 83: Signal Evaluation

    A, and if track B is low. Down count pulses are recorded at the positive edge at track A, and if track B is low. The diagram shows a single evaluation of signals: Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 84 B. The logic level at the signals A and B determines the count direction, i.e. the up or down count pulse. The diagram shows quadruple evaluation of signals: Signal A (A*) Signal B (B*) Up count pulses Down count pulses Down Figure 9-6 Quadruple evaluation Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 85 Encoder signals and their evaluation 9.5 Signal evaluation Default Single evaluation is set by default. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 86 Encoder signals and their evaluation 9.5 Signal evaluation Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 87: Assignment Of The Db

    27.0 ENSET_UP BOOL FALSE Enable setting in up direction (write user) 27.1 ENSET_DN BOOL FALSE Enable setting in down direction (write user) 27.2 A_BIT1_2 BOOL FALSE Reserved 27.3 A_BIT1_3 BOOL FALSE Reserved Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 88 STS_GATE BOOL FALSE Status internal gate (read user) 43.7 STS_SW_G BOOL FALSE Status SW gate (read user) 44.0 STS_SET BOOL FALSE Status digital input SET (read user) 44.1 STS_LATCH BOOL FALSE Reserved Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 89 FALSE RAM fault 57.4 ADU_FLT BOOL FALSE ADC/DAC fault 57.5 FUSE_FLT BOOL FALSE Fuse 57.6 HW_INTR_FLT BOOL FALSE Hardware interrupt lost 57.7 RESERVED_3 BOOL FALSE Reserved 58.0 CH_TYPE BYTE B#16#0 Channel type Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 90 DS1 byte 13 68.0 D_BYTE14 BYTE B#16#0 DS1 byte 14 69.0 D_BYTE15 BYTE B#16#0 DS1 byte 15 Variables in the DB that you have to/can enter or read out during work with the FM Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 91: Errors And Diagnostics

    Internal fault Fault in EPROM TEST Module replacement INTF diagnostics LED Fault in RAM TEST Module replacement Watchdog has responded Module replacement Process interrupt lost Is acknowledged by processing the process in‐ terrupt. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 92: Initiation Of Diagnostics Interrupts

    • Signal N faulty (wire breakage, short circuit, cable missing) Enabling the diagnostic interrupt You disable or enable the interrupts for the module and you choose whether the module is to initiate a diagnostic interrupt and/or a hardware interrupt. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 93 You can read out the diagnostic data record DS 1 and hence also the contents of DS0 from the module using FC DIAG_INF. This is only useful if DS0 signals an error in one channel. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 94 Always allocated to CH. 0 ... 7 Number of channels 2 is always assigned. Channel fault vector Bit 0 = 1: Fault on channel 1 Bit 1 = 1: Fault on channel 2 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 95: Data Error

    Data error When do data errors occur? If new parameters are transferred to the module, the FM 450-1 checks these parameters. If errors occur during this check, the module reports these data errors. Wrong parameters are not accepted by the module.
  • Page 96: Operator Error

    How are data errors acknowledged? Correct the values for the parameters to comply with the specifications. Transfer the corrected set of parameters to the FM 450-1 again. This again checks the parameters and deletes the data error in DB 1.
  • Page 97 Mode cannot be started using the SW gate. Mode cannot be aborted. Permitted only if OD is active How are operator errors acknowledged? Acknowledge the error with parameter OT_ERR_A in DB 1. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 98 Errors and diagnostics 11.5 Operator error Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 99: Technical Data

    Yes, toward all other voltages • Electrical isolation 5 V encoder power supply 5.2 V ± 2% • Output voltage Maximum 300 mA per count channel, short-circuit proof • Output current 24 V encoder power supply Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 100 + 11 ... + 28.8 V • High level Typically 9 mA • Input current ≥ 2.5 µs (200 kHz) • Minimum pulse width (maximum input fre‐ ≥ 25 µs (20 kHz) quency) (configurable) Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 101: Standards And Approvals

    Currently valid markings and approvals Introduction This section contains: • The standards and test values to which the FM 450-1 Counter Module complies and which it fulfills. • The test criteria according to which the FM 450-1 was tested. Technical specifications of the FM 450-1 Counter Module You can find the technical specifications of the FM 450-1 Counter Module in the equipment documentation.
  • Page 102: Ce Approval

    • Always be sure to de-energize the system before removing the plug connections. Note The FM 450-1 Counter Module is intended for use in industrial areas. If used in residential areas, it may interfere with radio/TV reception. 12.3.2...
  • Page 103: Ccc Approval

    Low-Voltage Directive 2014/35/EU "Electrical Equipment Designed for Use within Certain Voltage Limits" (Low-Voltage Directive) The FM 450-1 Counter Modules are tested according to the requirements of EN 61131-2, which fall under the Low-Voltage Directive. EMC Directive 2014/30/EU "Electromagnetic Compatibility" (EMC Directive) Use in industry SIMATIC products are designed for industrial applications.
  • Page 104: Ukca Approval

    Certificate number IECEx DEK 21.0008X Standards IEC 60079-0 IEC 60079-7 Marking Ex ec IIC T4 Gc The certificate is valid for the "IECEx DEK 21.0008X (https://support.industry.siemens.com/cs/document/ 109795939)". products listed in the certificate. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 105: Culus Approval

    • ANSI/ISA 12.12.01 • CSA C22.2 No. 213 (Hazardous Location) Approved for use in: Class I, Division 2, Group A, B, C, D Tx; Class I, Zone 2, Group IIC Tx 12.3.8 cFMus approval Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 106: Approval For Australia And New Zealand

    Note that this device corresponds to limit class A in terms of the emission of radio frequency interference. This device can be used in all areas, except residential areas. 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 107: Spare Parts

    Spare parts Spare parts The table lists all the spare parts for the FM 450-1 you can order for this module either additionally or at a later date. Table 13-1 Accessories and spare parts Parts for the FM 450-1 Order number...
  • Page 108 Spare parts Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 109: References

    (http:// Part of package support.automation.siemens.com/WW/view/en/1117849) 6ES7498-8AA04-8AA0 SIMATIC; System software for the S7-300/400 system and stand‐ Part of package ard functions (http://support.automation.siemens.com/WW/ 6ES7810-4CA07-8AW1 view/en/44240604) SIMATIC; S7-400 Automation System S7-400 Module Data (http://support.automation.siemens.com/WW/view/en/ 1117740) Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 110 References Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 111: Glossary

    A module which relieves the CPU of the S7 automation system of process signal processing tasks which are critical in time or memory-intensive. As a rule, FMs use the internal communication bus for high-speed data exchange with the CPU. Examples of FM applications: Counting, positioning, controlling Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 112 An SFC (system function) is an integrated function of the CPU operating system. The SFC can be called in the STEP 7 user program as required. Single evaluation Refers to a the evaluation of positive edges of the pulses at track A of an incremental encoder. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 113 The zero mark is positioned on the third track of an incremental encoder. It returns a zero mark signal after each rotation. Zero mark signal The incremental encoder returns one zero mark signal per revolution. Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 114 Glossary Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 115: Index

    Overview of commands, 58 count limits, 17 Overview of operating modes, 57 Count range, 17, 64 Settings overview, 58 Count range -31 to +31 bit, 64 Front connectors, 14 Terminal assignment, 25 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 116 Open and close SW gate, 60, 61, 63 START see digital inputs, 30 Opening and closing hardware gate, 63 Startup characteristics, 42 Operating modes, 57 Status bits, 59 Operator error, 96 STOP see digital inputs, 30 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 117 Index Supply of encoders, 28 SW gate Opening and closing the, 70 Status, 70 Symmetrical encoders, 80 VDC 5.2 encoder power supply, 28 Version, 13 View of module, 13 Zero crossing, 64 Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...
  • Page 118 Index Counter module FM 450-1 Equipment Manual, 03/2022, A5E03648739-AC...

This manual is also suitable for: