Accessories
11.3 DRIVE-CLiQ cabinet bushing
11.3.4.2
Installing the DRIVE-CLiQ cabinet bushing for M12 plug
Requirement
Risk of injury as a result of foreign bodies in the device
Parts (e.g.: drilling chips, end sleeves) falling into the device can cause short-circuits and
damage the insulation. This can result in severe injury (arcing, loud bang, parts that are flung
out).
• Only perform installation and other work when the devices are current-free.
• Cover the ventilation slots when mounting and installing the control cabinet and remove
Installation wall thickness: max. 4.5 mm
Procedure
Proceed as follows to install the DRIVE-CLiQ cabinet bushing in the cabinet panel:
①
Figure 11-5
276
WARNING
the cover before switching on.
Through-hole with chamfer
Through hole with an O-ring that can be screwed in from the inside
1 x 45°
1
max. 4,5 (0.18)
Equipment Manual, 09/2023, A5E53307519B AA
Booksize power units