11.3.4

Installation

11.3.4.1

Installing the DRIVE-CLiQ cabinet bushing for RJ45 plug

Requirement
Risk of injury as a result of foreign bodies in the device
Parts (e.g.: drilling chips, end sleeves) falling into the device can cause short-circuits and
damage the insulation. This can result in severe injury (arcing, loud bang, parts that are flung
out).
• Only perform installation and other work when the devices are current-free.
• Cover the ventilation slots when mounting and installing the control cabinet and remove
Procedure
Figure 11-4
Proceed as follows to install the DRIVE-CLiQ cabinet bushing in the cabinet panel:
1. Prepare the cutout in the control cabinet.
2. Insert the DRIVE-CLiQ cabinet bushing from the outside of the control cabinet through the
cutout in the control cabinet.
3. Attach the DRIVE-CLiQ cabinet bushing to the outside panel using 2 M3 screws and 2 nuts.
– Tightening torque: 0.8 Nm (7.1 lbf in)
– In order to ensure good electromagnetic compatibility, a good electrical connection must
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA
WARNING
the cover before switching on.
Outside of the control cabinet
M3 screw, tightening torque 0.8 Nm (7.1 lbf in)
Mounting and cutout in the control cabinet, all dimensions in mm and (inches)
be established between the DRIVE-CLiQ cabinet gland and the cabinet panel over a large
surface area.
Accessories
11.3 DRIVE-CLiQ cabinet bushing
275