Permissible Output Current At Low Frequencies - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

Motor Modules
8.4 Motor Modules 45 A and 60 A
Figure 8-44
8.4.6.3

Permissible output current at low frequencies

Technical data
The following diagram shows the permissible output current as a function of the output
frequency when operating with low output frequencies.
Figure 8-45
Output current at a low output frequency
For applications with a constant load, e.g. in paper machines, rolling mills etc., the output
current can be reduced as a function of the output frequency. To do this, the pulse frequency
must be set to a frequency less than 4 kHz.
198
Output current as a function of the pulse frequency
Booksize power units
Equipment Manual, 09/2023, A5E53307519B AA

Advertisement

Table of Contents
loading

Table of Contents